Xiu Zhou, Tian Tian, Peng Wu, Yan Luo, Jin Bai, Ninghui He, Xiuguang Li
{"title":"Mathematical modeling and experimental research on grounding current calculation of converter transformer core","authors":"Xiu Zhou, Tian Tian, Peng Wu, Yan Luo, Jin Bai, Ninghui He, Xiuguang Li","doi":"10.1177/00202940231187919","DOIUrl":null,"url":null,"abstract":"When the converter transformer core is grounded at multi-points, a fault loop will be formed and a circulation will be generated, leading to local overheating of the magnetic core and decomposition of insulating oil. Therefore, the converter transformer core will be single point grounded. As a rare internal lead of converter transformer, the ground current on the core ground lead can often reflect the running state of converter transformer. In this paper, theoretical analysis, modeling simulation and experimental research are carried out on the ground current of converter transformer at one point. Firstly, according to the structure characteristics of converter transformer, the analytical modeling of ground current is carried out. Secondly, based on the structure characteristics of oil paper insulation, the equivalent capacitance of converter transformer is calculated. Then, the analytical and finite element simulation model of converter transformer is established, and the ground current of converter transformer is calculated. Finally, the correctness of the proposed scheme is verified by measuring the grounding current of converter transformer core.","PeriodicalId":49849,"journal":{"name":"Measurement & Control","volume":"42 1","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement & Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/00202940231187919","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
When the converter transformer core is grounded at multi-points, a fault loop will be formed and a circulation will be generated, leading to local overheating of the magnetic core and decomposition of insulating oil. Therefore, the converter transformer core will be single point grounded. As a rare internal lead of converter transformer, the ground current on the core ground lead can often reflect the running state of converter transformer. In this paper, theoretical analysis, modeling simulation and experimental research are carried out on the ground current of converter transformer at one point. Firstly, according to the structure characteristics of converter transformer, the analytical modeling of ground current is carried out. Secondly, based on the structure characteristics of oil paper insulation, the equivalent capacitance of converter transformer is calculated. Then, the analytical and finite element simulation model of converter transformer is established, and the ground current of converter transformer is calculated. Finally, the correctness of the proposed scheme is verified by measuring the grounding current of converter transformer core.
期刊介绍:
Measurement and Control publishes peer-reviewed practical and technical research and news pieces from both the science and engineering industry and academia. Whilst focusing more broadly on topics of relevance for practitioners in instrumentation and control, the journal also includes updates on both product and business announcements and information on technical advances.