A CLINICAL CASE OF IMPACT BONE PLASTY IN THE REPLACEMENT OF DEFECTS IN THE ACETABULUM AND FEMORAL COMPONENT DURING REVISION HIP ENDOPROSTHETICS

IF 0.3 Q4 ORTHOPEDICS
Irina Kirilova, Vadim N. Golnik, Vladimir Peleganchuk, Yuriy Batrak, Vitaliy Pavlov
{"title":"A CLINICAL CASE OF IMPACT BONE PLASTY IN THE REPLACEMENT OF DEFECTS IN THE ACETABULUM AND FEMORAL COMPONENT DURING REVISION HIP ENDOPROSTHETICS","authors":"Irina Kirilova, Vadim N. Golnik, Vladimir Peleganchuk, Yuriy Batrak, Vitaliy Pavlov","doi":"10.17816/2311-2905-8008","DOIUrl":null,"url":null,"abstract":"Background. For many years, the main reasons for revision surgeries after hip arthroplasty remain aseptic loosening and osteolysis, which lead to formation of bone defects of various size and localization. Given the relatively young age of patients undergoing revision, the methods of biological restoration of the bone tissue, such as impaction bone grafting (IBG), are of particular interest.
 Aim of the report to demonstrate the delayed outcome of impaction bone grafting using compacted morselized bone allograft.
 Case presentation. Complicated clinical case of a 62-year-old patient with Paprosky type IIA bone deficiency in the acetabulum and Paprosky type II bone deficiency in the proximal femur with aseptic loosening of the acetabular and femoral components of the hip prosthesis is presented. During revision arthroplasty with cemented components, IBG of the acetabulum and femur was performed with a reconstructive mesh augmentation of the acetabulum using Stryker X-Change technology. Bone allograft prepared with the use of heat disinfection method served as an osteoplastic material. Follow-up period was 4 years. Control X-rays demonstrate restoration of the center of rotation of the hip, presence of bone masses in the areas of pelvic and femoral bone defects, absence of osteoplastic material resorption and migration of implants during the follow-up period. Clinical assessment shows an improvement of the Harris Hip Score from 34 to 85 points.
 Conclusion. Obtained results showed the efficacy of impaction bone grafting with the bone allograft prepared with the use of heat disinfection method in the mid-term period.","PeriodicalId":43463,"journal":{"name":"Travmatologiya i ortopediya Rossii","volume":"237 1","pages":"0"},"PeriodicalIF":0.3000,"publicationDate":"2023-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Travmatologiya i ortopediya Rossii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17816/2311-2905-8008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background. For many years, the main reasons for revision surgeries after hip arthroplasty remain aseptic loosening and osteolysis, which lead to formation of bone defects of various size and localization. Given the relatively young age of patients undergoing revision, the methods of biological restoration of the bone tissue, such as impaction bone grafting (IBG), are of particular interest. Aim of the report to demonstrate the delayed outcome of impaction bone grafting using compacted morselized bone allograft. Case presentation. Complicated clinical case of a 62-year-old patient with Paprosky type IIA bone deficiency in the acetabulum and Paprosky type II bone deficiency in the proximal femur with aseptic loosening of the acetabular and femoral components of the hip prosthesis is presented. During revision arthroplasty with cemented components, IBG of the acetabulum and femur was performed with a reconstructive mesh augmentation of the acetabulum using Stryker X-Change technology. Bone allograft prepared with the use of heat disinfection method served as an osteoplastic material. Follow-up period was 4 years. Control X-rays demonstrate restoration of the center of rotation of the hip, presence of bone masses in the areas of pelvic and femoral bone defects, absence of osteoplastic material resorption and migration of implants during the follow-up period. Clinical assessment shows an improvement of the Harris Hip Score from 34 to 85 points. Conclusion. Obtained results showed the efficacy of impaction bone grafting with the bone allograft prepared with the use of heat disinfection method in the mid-term period.
冲击骨成形术置换髋臼及股骨假体缺损一例
背景。多年来,髋关节置换术后翻修手术的主要原因仍然是无菌性松动和骨溶解,导致不同大小和定位的骨缺损的形成。考虑到接受翻修的患者相对年轻,骨组织的生物修复方法,如嵌塞骨移植(IBG),是特别感兴趣的。该报告的目的是证明使用压实的碎片化同种异体骨移植的嵌塞骨移植的延迟结果。案例演示。本文报道了一名62岁患者髋臼和股骨近端存在帕普洛斯基IIA型缺骨症,伴无菌性髋臼和股骨假体松动的复杂临床病例。在使用骨水泥假体翻修关节成形术期间,使用Stryker X-Change技术对髋臼进行重建网状物增强,对髋臼和股骨进行IBG。采用热消毒法制备的同种异体骨移植物作为成骨材料。随访4年。对照x光片显示髋关节旋转中心恢复,骨盆和股骨骨缺损区域存在骨团块,在随访期间没有骨塑材料吸收和植入物迁移。临床评估显示Harris髋关节评分从34分提高到85分。结论。结果表明,采用热消毒法制备的同种异体骨移植中期嵌塞植骨效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.60
自引率
66.70%
发文量
56
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信