Analytical Performance Evaluation of Hematology Analyzer Using Various TEa Sources and Sigma Metrics

IF 0.8 Q4 PATHOLOGY
Dereje Mengesha Berta, Mulugeta Melku, Tiruneh Adane, Mekonnen Girma, Zewudu Mulatie, Elias Chane, Bisrat Birke Teketelew
{"title":"Analytical Performance Evaluation of Hematology Analyzer Using Various TEa Sources and Sigma Metrics","authors":"Dereje Mengesha Berta, Mulugeta Melku, Tiruneh Adane, Mekonnen Girma, Zewudu Mulatie, Elias Chane, Bisrat Birke Teketelew","doi":"10.2147/plmi.s414693","DOIUrl":null,"url":null,"abstract":"Introduction: In clinical laboratory, the performance of the hematology analyzer should be checked routinely to ensure the desired quality. Therefore, the aim of the study was to assess the analytical performance of hematology analyzer using sigma metrics. Methods: The study included all daily internal quality control (IQC) data of hematology analyzer prospectively from August to October 2022. Data was collected using record formats by trained laboratory professionals. The sigma values of each CBC parameter were calculated using the formula: Sigma = (TEa – Bias) / CV. The TEa data were adopted from five different guidelines to calculate sigma value of the laboratory based on different specification. The bias of all complete blood count (CBC) parameters was calculated from the laboratory mean of the daily IQC data and the target value of the manufacturer in the insert kit. A coefficient of variations was also calculated using IQC data. Results: The current study found that sigma value of the analyzer varied based on source of TEa. Except HCT out 5 parameters included based on CLIA guideline, except MCV, MCHC, RDW, MPV and Basophil out of 15 parameters included based on EFLM 2022 minimum guideline, except Hb and PLT out of 9 parameters included based on SOTA guideline other parameters meets minimum specification (<3 sigma value). On the other hand, all parameters included in Rilibak and Standards of Spanish guideline achieved minimum specification (>3 sigma value). Conclusion: Sigma values of the CBC parameters have significantly varied depends on the TEa sources. So, it is recommended laboratory to use alternative sigma value based on its preference. Additionally, it is suggested that the laboratory to design local Westgard rules for each parameter based on sigma value.","PeriodicalId":88950,"journal":{"name":"Pathology and laboratory medicine international","volume":"22 1","pages":"0"},"PeriodicalIF":0.8000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pathology and laboratory medicine international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/plmi.s414693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: In clinical laboratory, the performance of the hematology analyzer should be checked routinely to ensure the desired quality. Therefore, the aim of the study was to assess the analytical performance of hematology analyzer using sigma metrics. Methods: The study included all daily internal quality control (IQC) data of hematology analyzer prospectively from August to October 2022. Data was collected using record formats by trained laboratory professionals. The sigma values of each CBC parameter were calculated using the formula: Sigma = (TEa – Bias) / CV. The TEa data were adopted from five different guidelines to calculate sigma value of the laboratory based on different specification. The bias of all complete blood count (CBC) parameters was calculated from the laboratory mean of the daily IQC data and the target value of the manufacturer in the insert kit. A coefficient of variations was also calculated using IQC data. Results: The current study found that sigma value of the analyzer varied based on source of TEa. Except HCT out 5 parameters included based on CLIA guideline, except MCV, MCHC, RDW, MPV and Basophil out of 15 parameters included based on EFLM 2022 minimum guideline, except Hb and PLT out of 9 parameters included based on SOTA guideline other parameters meets minimum specification (<3 sigma value). On the other hand, all parameters included in Rilibak and Standards of Spanish guideline achieved minimum specification (>3 sigma value). Conclusion: Sigma values of the CBC parameters have significantly varied depends on the TEa sources. So, it is recommended laboratory to use alternative sigma value based on its preference. Additionally, it is suggested that the laboratory to design local Westgard rules for each parameter based on sigma value.
使用不同TEa源和Sigma指标的血液分析仪分析性能评价
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信