{"title":"Three-Dimensional Heart Segmentation and Absolute Quantitation of Cardiac &lt;sup&gt;123&lt;/sup&gt;I-metaiodobenzylguanidine Sympathetic Imaging Using SPECT/CT","authors":"Shintaro Saito, Kenichi Nakajima, Takayuki Shibutani, Hiroshi Wakabayashi, Hiroto Yoneyama, Takahiro Konishi, Hiroshi Mori, Aki Takata, Seigo Kinuya","doi":"10.17996/anc.23-00002","DOIUrl":null,"url":null,"abstract":"Background: A three-dimensional (3D) approach to absolute quantitation of 123I-metaiodobenzylguanidine (MIBG) sympathetic nerve imaging using single-photon emission tomography (SPECT) / computed tomography (CT) is not available. Therefore, we calculated absolute cardiac counts and standardized uptake values (SUVs) from images of 72 consecutive patients with cardiac and neurological diseases using 123I-MIBG SPECT/CT and compared them with conventional planar quantitation. We aimed to develop new methods for 3D heart segmentation and the quantitation of these diseases. Methods: We manually segmented early and late SPECT/CT images of the heart in 3D, then calculated mean (SUVmean) and maximum (SUVmax) SUVs. We analyzed correlations between SUVs and planar heart-to-mediastinum ratios (HMRs), and between washout rates (WRs) derived from the SUVs and planar data. We also categorized WRs as normal or abnormal using linear regression lines determined by the relationship between SPECT/CT and planar WRs, and assessed agreement between them. Results: We calculated SUVmean and SUVmax from all early and late 123I-MIBG SPECT/CT images. Planar HMRs correlated with early and late SUVmean (R2=0.59 and 0.73, respectively) and SUVmax (R2=0.46 and 0.60, respectively; both p<0.0001). The SPECT/CT WRs determined based on SUVmean and SUVmax (R2=0.79 and 0.45, p<0.0001) closely correlated with planar WRs. Agreement of high and low WRs between planar WRs and SPECT/CT WRs calculated using SUVmax and SUVmean reached 88.1% and 94.4% respectively. Conclusions: We found that sympathetic nervous activity could be absolutely quantified in 3D from 123I-MIBG SPECT/CT images. Therefore, we propose a new method for quantifying sympathetic innervation on SPECT/CT images.","PeriodicalId":72228,"journal":{"name":"Annals of nuclear cardiology","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of nuclear cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17996/anc.23-00002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: A three-dimensional (3D) approach to absolute quantitation of 123I-metaiodobenzylguanidine (MIBG) sympathetic nerve imaging using single-photon emission tomography (SPECT) / computed tomography (CT) is not available. Therefore, we calculated absolute cardiac counts and standardized uptake values (SUVs) from images of 72 consecutive patients with cardiac and neurological diseases using 123I-MIBG SPECT/CT and compared them with conventional planar quantitation. We aimed to develop new methods for 3D heart segmentation and the quantitation of these diseases. Methods: We manually segmented early and late SPECT/CT images of the heart in 3D, then calculated mean (SUVmean) and maximum (SUVmax) SUVs. We analyzed correlations between SUVs and planar heart-to-mediastinum ratios (HMRs), and between washout rates (WRs) derived from the SUVs and planar data. We also categorized WRs as normal or abnormal using linear regression lines determined by the relationship between SPECT/CT and planar WRs, and assessed agreement between them. Results: We calculated SUVmean and SUVmax from all early and late 123I-MIBG SPECT/CT images. Planar HMRs correlated with early and late SUVmean (R2=0.59 and 0.73, respectively) and SUVmax (R2=0.46 and 0.60, respectively; both p<0.0001). The SPECT/CT WRs determined based on SUVmean and SUVmax (R2=0.79 and 0.45, p<0.0001) closely correlated with planar WRs. Agreement of high and low WRs between planar WRs and SPECT/CT WRs calculated using SUVmax and SUVmean reached 88.1% and 94.4% respectively. Conclusions: We found that sympathetic nervous activity could be absolutely quantified in 3D from 123I-MIBG SPECT/CT images. Therefore, we propose a new method for quantifying sympathetic innervation on SPECT/CT images.
三维心脏分割和心脏<sup>123</sup> i -甲氧苄基胍交感神经成像的绝对定量
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信