Validity, reliability and responsiveness of a goniometer watch to measure pure forearm rotation

IF 0.9 Q4 REHABILITATION
Daniel Harte, Alan Nevill, Lucia Ramsey, Suzanne Martin
{"title":"Validity, reliability and responsiveness of a goniometer watch to measure pure forearm rotation","authors":"Daniel Harte, Alan Nevill, Lucia Ramsey, Suzanne Martin","doi":"10.1177/17589983231211813","DOIUrl":null,"url":null,"abstract":"Introduction Innovative instruments have been designed to assess forearm rotation, an anatomically challenging motion to measure. This study assessed the concurrent validity, interrater reliability and responsiveness of a novel goniometer watch (GoWatch) to measure pure forearm rotation. The modified finger goniometer (MFG) was the criterion reference. Methods Forty participants with restricted forearm rotation were recruited. Two raters measured supination and pronation using the GoWatch and MFG before and after a hand therapy session. Repeated-measures ANOVA assessed for systematic bias with an apriori residual error of 5° deemed as acceptable. Secondary analysis used intraclass coefficients (ICCs) to categorise interrater reliability. Responsiveness of the GoWatch was calculated using Cohen’s d Results The GoWatch demonstrated acceptable agreement with the MFG with a mean difference for supination 1.19° and pronation 0.20°. Interrater reliability was also within acceptable limits with a mean difference GoWatch supination 4.43° and pronation 2.23°. Interrater reliability for GoWatch supination and pronation were categorized as excellent (ICC = 0.94) and good (ICC = 0.85) respectively. Systematic bias was observed in the instrument by rater interaction with rater two consistently underestimating GoWatch measures ( p<.05). GoWatch supination showed small to medium responsiveness (Rater 1: d = 0.14; Rater 2: d = 0.29) and pronation very small to medium responsiveness (Rater 1: d = 0.29; Rater 2: d = 0.05). Conclusion The GoWatch is a viable and user-friendly alternative to measure forearm rotation with demonstrable validity, interrater reliability and responsiveness. Further research is required to ensure systematic bias is not endemic when used across multiple raters.","PeriodicalId":43971,"journal":{"name":"Hand Therapy","volume":"81 11","pages":"0"},"PeriodicalIF":0.9000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hand Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17589983231211813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction Innovative instruments have been designed to assess forearm rotation, an anatomically challenging motion to measure. This study assessed the concurrent validity, interrater reliability and responsiveness of a novel goniometer watch (GoWatch) to measure pure forearm rotation. The modified finger goniometer (MFG) was the criterion reference. Methods Forty participants with restricted forearm rotation were recruited. Two raters measured supination and pronation using the GoWatch and MFG before and after a hand therapy session. Repeated-measures ANOVA assessed for systematic bias with an apriori residual error of 5° deemed as acceptable. Secondary analysis used intraclass coefficients (ICCs) to categorise interrater reliability. Responsiveness of the GoWatch was calculated using Cohen’s d Results The GoWatch demonstrated acceptable agreement with the MFG with a mean difference for supination 1.19° and pronation 0.20°. Interrater reliability was also within acceptable limits with a mean difference GoWatch supination 4.43° and pronation 2.23°. Interrater reliability for GoWatch supination and pronation were categorized as excellent (ICC = 0.94) and good (ICC = 0.85) respectively. Systematic bias was observed in the instrument by rater interaction with rater two consistently underestimating GoWatch measures ( p<.05). GoWatch supination showed small to medium responsiveness (Rater 1: d = 0.14; Rater 2: d = 0.29) and pronation very small to medium responsiveness (Rater 1: d = 0.29; Rater 2: d = 0.05). Conclusion The GoWatch is a viable and user-friendly alternative to measure forearm rotation with demonstrable validity, interrater reliability and responsiveness. Further research is required to ensure systematic bias is not endemic when used across multiple raters.
测量纯前臂旋转的角计表的有效性、可靠性和反应性
创新的仪器被设计用于评估前臂旋转,这是一个解剖学上具有挑战性的运动测量。本研究评估了一种新型测角表(GoWatch)测量纯前臂旋转的并发效度、互信度和反应性。改良手指测角仪(MFG)作为标准参考。方法招募40名前臂旋转受限的受试者。两名评分者在手部治疗前后分别使用GoWatch和MFG测量了手旋和旋前。重复测量方差分析评估系统偏倚,先验残差为5°被认为是可接受的。二级分析使用类内系数(ICCs)来分类间信度。GoWatch的响应性使用Cohen’s d进行计算。结果显示GoWatch与MFG具有可接受的一致性,旋后1.19°和旋前0.20°的平均差异。相互间的可靠性也在可接受的范围内,GoWatch旋后4.43°和旋前2.23°的平均差异。GoWatch旋前和旋前的可信度分别为优秀(ICC = 0.94)和良好(ICC = 0.85)。通过评分者与评分者2的相互作用,观察到仪器中存在系统性偏差,因为评分者始终低估了GoWatch的测量值(p< 0.05)。GoWatch旋转显示小到中等的响应性(Rater 1: d = 0.14;评分2:d = 0.29)和旋前非常小到中等的反应性(评分1:d = 0.29;比较2:d = 0.05)。结论GoWatch是一种可行且用户友好的测量前臂旋转的替代方法,具有可验证的效度、互信度和响应性。需要进一步的研究,以确保在跨多个评分者使用时,系统偏差不是地方性的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Hand Therapy
Hand Therapy REHABILITATION-
CiteScore
1.60
自引率
10.00%
发文量
13
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信