Effect of Submucosal Injection of Platelet-rich Plasma on the Rate of Canine Retraction – A Split-mouth Randomized Clinical Study

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Vinni Arora, Rekha Sharma, Davender Kumar, Gayathri Mohan, Anjali Narwal
{"title":"Effect of Submucosal Injection of Platelet-rich Plasma on the Rate of Canine Retraction – A Split-mouth Randomized Clinical Study","authors":"Vinni Arora, Rekha Sharma, Davender Kumar, Gayathri Mohan, Anjali Narwal","doi":"10.4103/ccd.ccd_567_22","DOIUrl":null,"url":null,"abstract":"Abstract Introduction: The use of platelet-rich plasma (PRP) has gained popularity in orthodontics in the past decade. PRP is an autologous concentration of platelets rich in growth factors and is hypothesized to play a role in orthodontic tooth movement (OTM) due to its bone remodeling capacity. Objective: The aim of this study was to determine the effect of PRP on the rate of tooth movement in humans. Materials and Methods: Fourteen patients requiring bilateral extraction of upper first premolars were included in the study. PRP (×4) was prepared and injected in the alveolar mucosa, distal to canine on experimental sides. Canine retraction was initiated on the same day of PRP injection using NiTi closed coil springs on both sides. The amount of canine retraction was measured and compared between both sides at the 4 th , 8 th , 12 th , and 16 th weeks by measuring the distance between lateral incisor and canine on the cast. Results: Results showed mean displacement of 1.355 mm, 1.232 mm, 1.191 mm, and 1.085 mm on experimental side and 1.265 mm, 1.126 mm, 1.031 mm, and 0.879 mm on control side at the 4 th , 8 th , 12 th , and 16 th weeks, respectively. Although increased OTM (13.85% or 1.1 times faster) was observed on experimental side at all time intervals compared to the control group, the result was not statistically significant. Conclusion: 4× concentration of PRP does not accelerate OTM significantly.","PeriodicalId":10632,"journal":{"name":"Contemporary Clinical Dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contemporary Clinical Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ccd.ccd_567_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Introduction: The use of platelet-rich plasma (PRP) has gained popularity in orthodontics in the past decade. PRP is an autologous concentration of platelets rich in growth factors and is hypothesized to play a role in orthodontic tooth movement (OTM) due to its bone remodeling capacity. Objective: The aim of this study was to determine the effect of PRP on the rate of tooth movement in humans. Materials and Methods: Fourteen patients requiring bilateral extraction of upper first premolars were included in the study. PRP (×4) was prepared and injected in the alveolar mucosa, distal to canine on experimental sides. Canine retraction was initiated on the same day of PRP injection using NiTi closed coil springs on both sides. The amount of canine retraction was measured and compared between both sides at the 4 th , 8 th , 12 th , and 16 th weeks by measuring the distance between lateral incisor and canine on the cast. Results: Results showed mean displacement of 1.355 mm, 1.232 mm, 1.191 mm, and 1.085 mm on experimental side and 1.265 mm, 1.126 mm, 1.031 mm, and 0.879 mm on control side at the 4 th , 8 th , 12 th , and 16 th weeks, respectively. Although increased OTM (13.85% or 1.1 times faster) was observed on experimental side at all time intervals compared to the control group, the result was not statistically significant. Conclusion: 4× concentration of PRP does not accelerate OTM significantly.
粘膜下注射富血小板血浆对犬后缩率的影响——一项裂口随机临床研究
摘要简介:近十年来,富血小板血浆(PRP)在正畸治疗中的应用越来越广泛。PRP是一种富含生长因子的血小板的自体浓度,由于其骨重塑能力,被假设在正畸牙齿运动(OTM)中发挥作用。目的:本研究的目的是确定PRP对人类牙齿移动速度的影响。材料与方法:选取14例需要双侧拔除上颌第一前磨牙的患者作为研究对象。制备PRP (×4)并注射于实验侧犬齿远端牙槽黏膜。在PRP注射当天,犬用双侧NiTi闭合螺旋弹簧开始牵开。在第4周、第8周、第12周和第16周,通过测量铸型上侧切牙与犬齿之间的距离,测量并比较两侧犬齿的内收量。结果:第4周、第8周、第12周、第16周,实验侧平均位移分别为1.355 mm、1.232 mm、1.191 mm、1.085 mm,对照侧平均位移为1.265 mm、1.126 mm、1.031 mm、0.879 mm。虽然与对照组相比,实验侧各时间间隔的OTM均增加(13.85%或1.1倍),但结果无统计学意义。结论:4倍浓度的PRP对OTM无显著促进作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Contemporary Clinical Dentistry
Contemporary Clinical Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.50
自引率
0.00%
发文量
52
审稿时长
23 weeks
期刊介绍: The journal Contemporary Clinical Dentistry (CCD) (Print ISSN: 0976-237X, E-ISSN:0976- 2361) is peer-reviewed journal published on behalf of Maharishi Markandeshwar University and issues are published quarterly in the last week of March, June, September and December. The Journal publishes Original research papers, clinical studies, case series strictly of clinical interest. Manuscripts are invited from all specialties of Dentistry i.e. Conservative dentistry and Endodontics, Dentofacial orthopedics and Orthodontics, Oral medicine and Radiology, Oral pathology, Oral surgery, Orodental diseases, Pediatric Dentistry, Periodontics, Clinical aspects of Public Health dentistry and Prosthodontics. Review articles are not accepted. Review, if published, will only be by invitation from eminent scholars and academicians of National and International repute in the field of Medical/Dental education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信