Human-Mimic Submuscular and Premuscular Irradiated Rat Model: Histologic Characteristics of the Capsule Tissue in Contact with the Breast Implant

IF 1.9 4区 医学 Q3 OBSTETRICS & GYNECOLOGY
Hyung Bae Kim, Se Young Han, Jin Sup Eom, Hyun Ho Han
{"title":"Human-Mimic Submuscular and Premuscular Irradiated Rat Model: Histologic Characteristics of the Capsule Tissue in Contact with the Breast Implant","authors":"Hyung Bae Kim, Se Young Han, Jin Sup Eom, Hyun Ho Han","doi":"10.1155/2023/4363272","DOIUrl":null,"url":null,"abstract":"Background. In this study, we established two rat models that mimic human submuscular and premuscular breast reconstruction. We analyzed the capsule formation according to surgical techniques and adjacent tissues, including the chest wall tissues, such as the ribs and acellular dermal matrices (ADMs) that come in contact with silicone implants. Methods. This study consisted of experiments on 12 Sprague–Dawley rats that underwent implant reconstruction using ADM. They were divided into two groups: rats that underwent dual-plane implantation (n = 6; group 1) and those that underwent premuscular implant insertion (n = 6; group 2). All rats were irradiated with 35 Gy of fractionated radiation. Three months after surgery, the histology and immunochemistry of the capsule tissues of the ADM, muscle, and chest wall were analyzed. Results. Overall capsule thickness was thicker in group 1. Based on the tissue in contact with the silicone implant, ADM had a thinner capsule, less inflammation, less fibrosis, and less vascularization than the muscle and chest wall tissues. Conclusions. This study described two rat models of clinically relevant implant-based breast reconstruction using a submuscular and premuscular plane, ADM, and irradiation. Overall, the premuscular implantation rat model was associated with a thinner capsule. The ADM in contact with the silicone implant, even after irradiation, had superior protection from radiation compared with the other tissues.","PeriodicalId":56326,"journal":{"name":"Breast Journal","volume":" 10","pages":"0"},"PeriodicalIF":1.9000,"publicationDate":"2023-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Breast Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/4363272","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background. In this study, we established two rat models that mimic human submuscular and premuscular breast reconstruction. We analyzed the capsule formation according to surgical techniques and adjacent tissues, including the chest wall tissues, such as the ribs and acellular dermal matrices (ADMs) that come in contact with silicone implants. Methods. This study consisted of experiments on 12 Sprague–Dawley rats that underwent implant reconstruction using ADM. They were divided into two groups: rats that underwent dual-plane implantation (n = 6; group 1) and those that underwent premuscular implant insertion (n = 6; group 2). All rats were irradiated with 35 Gy of fractionated radiation. Three months after surgery, the histology and immunochemistry of the capsule tissues of the ADM, muscle, and chest wall were analyzed. Results. Overall capsule thickness was thicker in group 1. Based on the tissue in contact with the silicone implant, ADM had a thinner capsule, less inflammation, less fibrosis, and less vascularization than the muscle and chest wall tissues. Conclusions. This study described two rat models of clinically relevant implant-based breast reconstruction using a submuscular and premuscular plane, ADM, and irradiation. Overall, the premuscular implantation rat model was associated with a thinner capsule. The ADM in contact with the silicone implant, even after irradiation, had superior protection from radiation compared with the other tissues.
模拟人肌下和肌前辐射大鼠模型:与乳房植入物接触的胶囊组织的组织学特征
背景。在这项研究中,我们建立了两个模拟人类肌肉下和肌肉前乳房重建的大鼠模型。我们根据手术技术和邻近组织,包括胸壁组织,如肋骨和脱细胞真皮基质(ADMs),与硅胶植入物接触,分析了胶囊的形成。方法。本研究选取12只采用adm进行种植体重建的Sprague-Dawley大鼠进行实验,分为两组:双平面种植大鼠(n = 6;组1)和肌前植入组(n = 6;2组)。所有大鼠均接受35 Gy的分次辐射照射。术后3个月对ADM、肌肉、胸壁的包膜组织进行组织学和免疫化学分析。结果。1组被囊总厚度较厚。与硅胶植入物接触的组织相比,ADM的包膜更薄,炎症更少,纤维化更少,血管化更少。结论。本研究描述了采用肌下和肌前平面、ADM和照射的两种临床相关的基于假体的乳房重建大鼠模型。总的来说,肌肉植入前大鼠模型与更薄的胶囊相关。与其他组织相比,与硅胶植入物接触的ADM即使在辐照后也具有更好的防辐射能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Breast Journal
Breast Journal 医学-妇产科学
CiteScore
4.00
自引率
0.00%
发文量
47
审稿时长
4-8 weeks
期刊介绍: The Breast Journal is the first comprehensive, multidisciplinary source devoted exclusively to all facets of research, diagnosis, and treatment of breast disease. The Breast Journal encompasses the latest news and technologies from the many medical specialties concerned with breast disease care in order to address the disease within the context of an integrated breast health care. This editorial philosophy recognizes the special social, sexual, and psychological considerations that distinguish cancer, and breast cancer in particular, from other serious diseases. Topics specifically within the scope of The Breast Journal include: Risk Factors Prevention Early Detection Diagnosis and Therapy Psychological Issues Quality of Life Biology of Breast Cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信