{"title":"Denture Base Polymer Biodegradation: In Vitro Study","authors":"Alessandra-Aniela Cerghedi, Zita Fazakas, Melinda Székely, Carmen Biriș, Cristina Molnar-Varlam","doi":"10.2478/jim-2023-0005","DOIUrl":null,"url":null,"abstract":"Abstract Introduction Acrylic resins are the most frequently used materials for the bases of prostheses, and are also used in the re-optimization and the repair of prostheses. The aim of our study was to investigate whether direct contact with the resin causes decomposition of methyl methacrylate and formation of ketone bodies in the oral cavity. Material and methods The in vitro study included 12 samples of autopolymerized polymethyl methacrylate and 8 samples of thermopolymerized polymethyl methacrylate. Some of the resin samples were intentionally prepared incorrectly, with modified powder to liquid ratios or thermal regime, to be able to compare them with samples prepared according to the manufacturer’s instructions. Some of the samples were immersed in gastric juice or alcohol for 48 h at 37 °C in a thermostatic bath to simulate the environment and temperature of the oral cavity, while others were kept at room temperature. The Legal reaction was used to identify the presence of ketone bodies in the solutions. Results The samples that were prepared incorrectly and were kept at 37 °C were the most affected. The presence of ketone bodies was demonstrated by the formation of a precipitate on the bottom of the test tube and the color change of the solution. Samples that were kept at room temperature were less affected, both from a spectrophotometric and biochemical point of view. Conclusion The quality of polymethyl methacrylate can be improved by respecting the manufacturer’s instructions and work protocols, and by avoiding substances that are considered aggressive, such as gastric juice, alcohol, and local factors in the oral cavity.","PeriodicalId":234618,"journal":{"name":"Journal of Interdisciplinary Medicine","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Interdisciplinary Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/jim-2023-0005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Introduction Acrylic resins are the most frequently used materials for the bases of prostheses, and are also used in the re-optimization and the repair of prostheses. The aim of our study was to investigate whether direct contact with the resin causes decomposition of methyl methacrylate and formation of ketone bodies in the oral cavity. Material and methods The in vitro study included 12 samples of autopolymerized polymethyl methacrylate and 8 samples of thermopolymerized polymethyl methacrylate. Some of the resin samples were intentionally prepared incorrectly, with modified powder to liquid ratios or thermal regime, to be able to compare them with samples prepared according to the manufacturer’s instructions. Some of the samples were immersed in gastric juice or alcohol for 48 h at 37 °C in a thermostatic bath to simulate the environment and temperature of the oral cavity, while others were kept at room temperature. The Legal reaction was used to identify the presence of ketone bodies in the solutions. Results The samples that were prepared incorrectly and were kept at 37 °C were the most affected. The presence of ketone bodies was demonstrated by the formation of a precipitate on the bottom of the test tube and the color change of the solution. Samples that were kept at room temperature were less affected, both from a spectrophotometric and biochemical point of view. Conclusion The quality of polymethyl methacrylate can be improved by respecting the manufacturer’s instructions and work protocols, and by avoiding substances that are considered aggressive, such as gastric juice, alcohol, and local factors in the oral cavity.
义齿基托聚合物生物降解的体外研究
摘要简介丙烯酸树脂是义肢最常用的基板材料,在义肢的再优化和修复中也有广泛的应用。我们的研究目的是探讨直接接触树脂是否会导致口腔内甲基丙烯酸甲酯的分解和酮体的形成。材料与方法体外实验采用自聚合聚甲基丙烯酸甲酯12个样品和热聚合聚甲基丙烯酸甲酯8个样品。有些树脂样品是故意不正确地制备的,通过修改粉液比或热状态,以便能够将它们与根据制造商说明制备的样品进行比较。部分样品在37°C的恒温浴液中浸泡胃液或酒精48 h,模拟口腔环境和温度,其余样品在室温下保存。用法制反应来鉴定溶液中是否存在酮体。结果制备方法不正确且保存于37℃的样品受影响最大。通过在试管底部形成沉淀和溶液的颜色变化来证明酮体的存在。从分光光度和生化的角度来看,在室温下保存的样品受到的影响较小。结论遵守生产厂家的说明书和作业规程,避免胃液、酒精和口腔局部因素等具有侵蚀性的物质,可提高聚甲基丙烯酸甲酯的质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信