Calibration and error analysis of an arc detector for wide-angle X-ray scattering (WAXS)

IF 1.3 4区 工程技术 Q4 CHEMISTRY, ANALYTICAL
Xiaoxia Shang, Rongchao Chen, Haijuan Wu, Yueqian Fan, Meijun Wang, Zhihong Li, Liping Chang, Jiangang Chen
{"title":"Calibration and error analysis of an arc detector for wide-angle X-ray scattering (WAXS)","authors":"Xiaoxia Shang, Rongchao Chen, Haijuan Wu, Yueqian Fan, Meijun Wang, Zhihong Li, Liping Chang, Jiangang Chen","doi":"10.1080/10739149.2023.2280188","DOIUrl":null,"url":null,"abstract":"AbstractIn wide-angle X-ray scattering (WAXS) experiments, the use of a one-dimensional arc detector can effectively expand the angle range of collected diffraction or scattering signals. In practice, the relative positions between the centers of arc detector, sample and beam spot may overlap or misalign. Therefore, it is necessary to calibrate the instrument parameters and detection angle of the arc detector. The calibration is routinely performed by standard samples. In this contribution, the equations for angle calibration and error evaluation are constructed based on three standard diffraction peaks, and the corresponding simulation and experiment are performed to verify the feasibility of the calibration. The results indicate that the larger the coverage and the more uniform the dispersion of the three standard diffraction peaks distributed on the detector, the smaller the calibration error.Keywords: Wide-angle X-ray scattering (WAXS)one-dimensional arc detectorangle calibration AcknowledgementThe authors thank Zhonghua Wu, Zhongjun Chen, Zhan Shi, Xueqing Xing, Lei Yao and Hao Wang for their help with the WAXS experiments.Disclosure statementNo conflicts of interest are reported by the authors.Additional informationFundingThis work was supported by the National Key R & D Program of China [grant number 2017YFA0403000], the National Natural Science Foundation of China [grants number U1910206, 22278295, 22378291 and U1910201] and the Key R & D projects in Shanxi Province [grant number 202102090301002], and the National Key Laboratory of High Efficiency and Low Carbon Utilization of Coal [grants number J23-24-612].","PeriodicalId":13547,"journal":{"name":"Instrumentation Science & Technology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instrumentation Science & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10739149.2023.2280188","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

AbstractIn wide-angle X-ray scattering (WAXS) experiments, the use of a one-dimensional arc detector can effectively expand the angle range of collected diffraction or scattering signals. In practice, the relative positions between the centers of arc detector, sample and beam spot may overlap or misalign. Therefore, it is necessary to calibrate the instrument parameters and detection angle of the arc detector. The calibration is routinely performed by standard samples. In this contribution, the equations for angle calibration and error evaluation are constructed based on three standard diffraction peaks, and the corresponding simulation and experiment are performed to verify the feasibility of the calibration. The results indicate that the larger the coverage and the more uniform the dispersion of the three standard diffraction peaks distributed on the detector, the smaller the calibration error.Keywords: Wide-angle X-ray scattering (WAXS)one-dimensional arc detectorangle calibration AcknowledgementThe authors thank Zhonghua Wu, Zhongjun Chen, Zhan Shi, Xueqing Xing, Lei Yao and Hao Wang for their help with the WAXS experiments.Disclosure statementNo conflicts of interest are reported by the authors.Additional informationFundingThis work was supported by the National Key R & D Program of China [grant number 2017YFA0403000], the National Natural Science Foundation of China [grants number U1910206, 22278295, 22378291 and U1910201] and the Key R & D projects in Shanxi Province [grant number 202102090301002], and the National Key Laboratory of High Efficiency and Low Carbon Utilization of Coal [grants number J23-24-612].
广角x射线散射电弧探测器(WAXS)标定及误差分析
摘要在广角x射线散射(WAXS)实验中,利用一维电弧探测器可以有效地扩大采集到的衍射或散射信号的角度范围。在实际应用中,圆弧探测器中心、样品中心和光束光斑之间的相对位置可能会重叠或不对齐。因此,有必要对电弧检测仪的仪器参数和检测角度进行校准。校准通常由标准样品进行。本文建立了基于三个标准衍射峰的角度标定和误差评定方程,并进行了相应的仿真和实验验证了标定的可行性。结果表明,三个标准衍射峰分布在探测器上的覆盖范围越大,色散越均匀,标定误差越小。感谢吴中华、陈中军、石展、邢学清、姚磊、王浩对广角x射线散射(WAXS)实验的帮助。披露声明作者无利益冲突报告。基金资助:国家重点研发计划项目[批准号2017YFA0403000],国家自然科学基金项目[批准号U1910206, 22278295, 22378291和U1910201],山西省重点研发项目[批准号202102090301002],煤炭高效低碳利用国家重点实验室[批准号J23-24-612]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Instrumentation Science & Technology
Instrumentation Science & Technology 工程技术-分析化学
CiteScore
3.50
自引率
0.00%
发文量
45
审稿时长
>12 weeks
期刊介绍: Instrumentation Science & Technology is an internationally acclaimed forum for fast publication of critical, peer reviewed manuscripts dealing with innovative instrument design and applications in chemistry, physics biotechnology and environmental science. Particular attention is given to state-of-the-art developments and their rapid communication to the scientific community. Emphasis is on modern instrumental concepts, though not exclusively, including detectors, sensors, data acquisition and processing, instrument control, chromatography, electrochemistry, spectroscopy of all types, electrophoresis, radiometry, relaxation methods, thermal analysis, physical property measurements, surface physics, membrane technology, microcomputer design, chip-based processes, and more. Readership includes everyone who uses instrumental techniques to conduct their research and development. They are chemists (organic, inorganic, physical, analytical, nuclear, quality control) biochemists, biotechnologists, engineers, and physicists in all of the instrumental disciplines mentioned above, in both the laboratory and chemical production environments. The journal is an important resource of instrument design and applications data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信