{"title":"End-to-end Standardization of Original Medicines when Determining Related Impurities","authors":"Yu. E. Generalova, I. I. Terninko, A. B. Zelentsova","doi":"10.33380/2305-2066-2023-12-4-1573","DOIUrl":null,"url":null,"abstract":"Introduction. For tablets “Malоben, 60 mg” and “Etmaben, 300 mg”, permission was received to conduct phase I clinical trials, so they required a full cycle of research and standardization. Aim. Development of a unified analytical procedure for the determination of related impurities in samples (RS, API, FPP) of Malоben and Ethmaben. Materials and methods. RSs were obtained at the Department of Organic Chemistry of the St. Petersburg State Chemical and Pharmaceutical University; the synthesis of APIs and the production of FPP were carried out on an industrial scale in pharmaceutical production. The studies were carried out on a Flexar liquid chromatograph (PerkinElmer, USA), equipped with a pump (formation of a gradient on the low-pressure side), an autosampler, a column thermostat, a UV detector and a chromatographic column Intersil® ODS-3V, 5 µm, 100 Å, 250 × 4, 6 (Phenomenex, Japan). Results and discussion. In the research, uniform optimal chromatographic conditions were selected using the HPLC method to determine the RP in RS, API and FPP of Maloben and Ethmaben. Column C18 250×4.6 mm, mobile phase 0.1% phosphoric acid and acetonitrile (gradient elution), flow rate 1 ml/min, sample volume 10 µl, UV detector (270 nm). They were validated in terms of specificity, linearity, detection limit, precision, robustness, and solution stability. Analytical concentration levels were selected for the formation of draft regulatory documents. Using the developed analytical technique, samples of RS, API and tablets of malоben and ethmaben were analyzed. Conclusion. A full cycle of research was carried out, an analytical methodology was developed and related impurities were identified in RS, API and FPP of Maloben and Ethmaben.","PeriodicalId":36465,"journal":{"name":"Drug Development and Registration","volume":"96 12","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Development and Registration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33380/2305-2066-2023-12-4-1573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction. For tablets “Malоben, 60 mg” and “Etmaben, 300 mg”, permission was received to conduct phase I clinical trials, so they required a full cycle of research and standardization. Aim. Development of a unified analytical procedure for the determination of related impurities in samples (RS, API, FPP) of Malоben and Ethmaben. Materials and methods. RSs were obtained at the Department of Organic Chemistry of the St. Petersburg State Chemical and Pharmaceutical University; the synthesis of APIs and the production of FPP were carried out on an industrial scale in pharmaceutical production. The studies were carried out on a Flexar liquid chromatograph (PerkinElmer, USA), equipped with a pump (formation of a gradient on the low-pressure side), an autosampler, a column thermostat, a UV detector and a chromatographic column Intersil® ODS-3V, 5 µm, 100 Å, 250 × 4, 6 (Phenomenex, Japan). Results and discussion. In the research, uniform optimal chromatographic conditions were selected using the HPLC method to determine the RP in RS, API and FPP of Maloben and Ethmaben. Column C18 250×4.6 mm, mobile phase 0.1% phosphoric acid and acetonitrile (gradient elution), flow rate 1 ml/min, sample volume 10 µl, UV detector (270 nm). They were validated in terms of specificity, linearity, detection limit, precision, robustness, and solution stability. Analytical concentration levels were selected for the formation of draft regulatory documents. Using the developed analytical technique, samples of RS, API and tablets of malоben and ethmaben were analyzed. Conclusion. A full cycle of research was carried out, an analytical methodology was developed and related impurities were identified in RS, API and FPP of Maloben and Ethmaben.
原料药相关杂质测定的端到端标准化
介绍。对于“malcovben, 60毫克”和“Etmaben, 300毫克”片剂,获得了进行I期临床试验的许可,因此它们需要一个完整的研究和标准化周期。的目标。制定了一套统一的分析程序,用于测定马尔伐本和乙马苯样品(RS, API, FPP)中相关杂质的含量。材料和方法。RSs在圣彼得堡国立化学与制药大学有机化学系获得;原料药的合成和FPP的生产在医药生产中实现了工业化规模。研究在Flexar液相色谱仪(PerkinElmer,美国)上进行,配备泵(在低压侧形成梯度),自动进样器,柱恒温器,紫外检测器和色谱柱Intersil®ODS-3V, 5µm, 100 Å, 250 × 4,6 (Phenomenex,日本)。结果和讨论。本研究选择了统一的最佳色谱条件,采用高效液相色谱法测定了美洛宾和乙马苯的RS、API和FPP中的RP。柱C18 250×4.6 mm,流动相0.1%磷酸和乙腈(梯度洗脱),流速1 ml/min,进样量10µl,紫外检测器(270 nm)。在特异性、线性度、检出限、精密度、鲁棒性和溶液稳定性方面进行了验证。分析浓度水平被选择用于形成法规文件草案。采用新开发的分析技术,对原料药、原料药和马伐本、乙马苯片进行了分析。结论。进行了完整周期的研究,建立了分析方法,并在马洛宾和乙马苯的RS、API和FPP中鉴定了相关杂质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Drug Development and Registration
Drug Development and Registration Pharmacology, Toxicology and Pharmaceutics-Pharmaceutical Science
CiteScore
1.20
自引率
0.00%
发文量
61
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信