On the use of NHZ-203C Thermoluminescence (TL) reader in clinical dosimetry.

Radiobiologia, radiotherapia Pub Date : 1990-01-01
P Zaránd, I Polgár, E Katona
{"title":"On the use of NHZ-203C Thermoluminescence (TL) reader in clinical dosimetry.","authors":"P Zaránd,&nbsp;I Polgár,&nbsp;E Katona","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The sensitivity vs. dose characteristics of two TL readers (Harshaw 2000 A + B and NHZ-203C) was compared both in the range of small doses (10 microGy to 100 mGy) as well as in the radiation therapy level by using individually calibrated LiF:Mg, Ti detectors manufactured in Poland. The performance of both systems can be predicted by a three parameter theoretical model. The very good reproducibility of the NHZ-203C reader (sigma/D = 0.6%) is important in radiation therapy while the high sensitivity (the lowest detectable dose limit = 3 S.D. of the background = 27 microGy) is useful for radiation protection measurements.</p>","PeriodicalId":76404,"journal":{"name":"Radiobiologia, radiotherapia","volume":"31 2","pages":"151-4"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiobiologia, radiotherapia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The sensitivity vs. dose characteristics of two TL readers (Harshaw 2000 A + B and NHZ-203C) was compared both in the range of small doses (10 microGy to 100 mGy) as well as in the radiation therapy level by using individually calibrated LiF:Mg, Ti detectors manufactured in Poland. The performance of both systems can be predicted by a three parameter theoretical model. The very good reproducibility of the NHZ-203C reader (sigma/D = 0.6%) is important in radiation therapy while the high sensitivity (the lowest detectable dose limit = 3 S.D. of the background = 27 microGy) is useful for radiation protection measurements.

NHZ-203C热释光(TL)阅读器在临床剂量测定中的应用。
通过使用波兰制造的单独校准的LiF:Mg, Ti探测器,比较了两种TL读取器(Harshaw 2000 A + B和NHZ-203C)在小剂量范围(10 microGy至100 mGy)和放射治疗水平的灵敏度与剂量特性。两种系统的性能都可以用一个三参数理论模型来预测。NHZ-203C阅读器良好的再现性(sigma/D = 0.6%)在放射治疗中具有重要意义,而高灵敏度(最低可检测剂量限= 3sd,本底= 27 microGy)对辐射防护测量很有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信