{"title":"Evaluation of radon mitigation systems in 14 houses over a two-year period.","authors":"R J Prill, W J Fisk, B H Turk","doi":"10.1080/10473289.1990.10466719","DOIUrl":null,"url":null,"abstract":"<p><p>Fourteen single-family detached houses in Spokane, Washington, and Coeur D'Alene, Idaho, were monitored for two years after high concentrations of indoor radon had been mitigated. Each house was monitored quarterly using mailed alpha-track radon detectors deployed in each zone of the structure. To assess performance of mitigation systems during the second heating season after mitigation, radon concentrations in seven houses were monitored continuously for several weeks, mitigation systems in all houses were inspected, and selected other measurements were taken. In addition, occupants were also interviewed regarding their maintenance, operation, and subjective evaluation of the radon mitigation systems. Quarterly alpha-track measurements showed that radon levels had increased in most of the homes during many follow-up measurement periods when compared with concentrations measured immediately after mitigation. Mitigation-system performance was adversely affected by (1) accumulated outdoor debris blocking the outlets of subsurface pressurization pipes; (2) fans being turned off (e.g., because of excessive noise or vibration); (3) air-to-air heat exchanger, basement pressurization, and subsurface ventilation fans being turned off and fan speeds reduced; and (4) crawl-space vents being closed or sealed.</p>","PeriodicalId":17202,"journal":{"name":"Journal of the Air & Waste Management Association","volume":"40 5","pages":"740-8"},"PeriodicalIF":2.7000,"publicationDate":"1990-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/10473289.1990.10466719","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Air & Waste Management Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10473289.1990.10466719","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
Fourteen single-family detached houses in Spokane, Washington, and Coeur D'Alene, Idaho, were monitored for two years after high concentrations of indoor radon had been mitigated. Each house was monitored quarterly using mailed alpha-track radon detectors deployed in each zone of the structure. To assess performance of mitigation systems during the second heating season after mitigation, radon concentrations in seven houses were monitored continuously for several weeks, mitigation systems in all houses were inspected, and selected other measurements were taken. In addition, occupants were also interviewed regarding their maintenance, operation, and subjective evaluation of the radon mitigation systems. Quarterly alpha-track measurements showed that radon levels had increased in most of the homes during many follow-up measurement periods when compared with concentrations measured immediately after mitigation. Mitigation-system performance was adversely affected by (1) accumulated outdoor debris blocking the outlets of subsurface pressurization pipes; (2) fans being turned off (e.g., because of excessive noise or vibration); (3) air-to-air heat exchanger, basement pressurization, and subsurface ventilation fans being turned off and fan speeds reduced; and (4) crawl-space vents being closed or sealed.
期刊介绍:
The Journal of the Air & Waste Management Association (J&AWMA) is one of the oldest continuously published, peer-reviewed, technical environmental journals in the world. First published in 1951 under the name Air Repair, J&AWMA is intended to serve those occupationally involved in air pollution control and waste management through the publication of timely and reliable information.