Comparison of Carotid Artery Dose in Early-Stage Glottic Cancer Treated with 3D-Conformal, Helical-IMRT and VMAT

Q4 Medicine
B Pires, D Rothwell, I Guimarães, J Sousa, R Magalhães, T Serra, L Khouri, P Alves
{"title":"Comparison of Carotid Artery Dose in Early-Stage Glottic Cancer Treated with 3D-Conformal, Helical-IMRT and VMAT","authors":"B Pires, D Rothwell, I Guimarães, J Sousa, R Magalhães, T Serra, L Khouri, P Alves","doi":"10.2478/fco-2023-0009","DOIUrl":null,"url":null,"abstract":"Abstract Background The aim of this study was to compare the dosimetry of carotid arteries (CAs) using three radiation therapy (RT) techniques, three-dimensional conformal RT (3D-CRT), helical tomotherapy-intensity-modulated RT (HT-IMRT), and volumetric modulated arc therapy (VMAT), in patients with early-stage glottic cancer. Patients and Methods A retrospective analysis of 28 patients was performed, and the right and left CAs were delineated. Mean and maximum dose (Dmax) values were compared across the three treatment techniques. Results The results indicate that 3D-CRT plans had the highest mean and maximum doses to CAs, while VMAT plans had the lowest doses. Conclusions Our study demonstrates the feasibility of sparing CAs with newer RT modalities. Further clinical studies are needed to determine if these techniques can reduce carotid stenosis-related events.","PeriodicalId":38592,"journal":{"name":"Forum of Clinical Oncology","volume":"52 29","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forum of Clinical Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/fco-2023-0009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background The aim of this study was to compare the dosimetry of carotid arteries (CAs) using three radiation therapy (RT) techniques, three-dimensional conformal RT (3D-CRT), helical tomotherapy-intensity-modulated RT (HT-IMRT), and volumetric modulated arc therapy (VMAT), in patients with early-stage glottic cancer. Patients and Methods A retrospective analysis of 28 patients was performed, and the right and left CAs were delineated. Mean and maximum dose (Dmax) values were compared across the three treatment techniques. Results The results indicate that 3D-CRT plans had the highest mean and maximum doses to CAs, while VMAT plans had the lowest doses. Conclusions Our study demonstrates the feasibility of sparing CAs with newer RT modalities. Further clinical studies are needed to determine if these techniques can reduce carotid stenosis-related events.
3d适形、螺旋imrt和VMAT治疗早期声门癌颈动脉剂量的比较
背景本研究的目的是比较三种放射治疗(RT)技术,三维适形放射治疗(3D-CRT),螺旋放射治疗-强度调节放射治疗(HT-IMRT)和体积调节弧线治疗(VMAT)对早期声门癌患者颈动脉(CAs)的剂量测定。患者与方法对28例患者进行回顾性分析,并划分左、右ca。比较三种治疗方法的平均和最大剂量(Dmax)值。结果3D-CRT计划对ca的平均和最大剂量最高,VMAT计划对ca的平均和最大剂量最低。结论:我们的研究证明了使用更新的放疗方式保留ca的可行性。需要进一步的临床研究来确定这些技术是否可以减少颈动脉狭窄相关事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Forum of Clinical Oncology
Forum of Clinical Oncology Medicine-Oncology
CiteScore
0.50
自引率
0.00%
发文量
3
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信