[Use of the balloon catheter in dilatation of corrosive stenosis of the esophagus].

Ceskoslovenska otolaryngologie Pub Date : 1990-02-01
M Pokorný
{"title":"[Use of the balloon catheter in dilatation of corrosive stenosis of the esophagus].","authors":"M Pokorný","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>During the period between October 1985 and the end of March 1988 from a total number of 269 dilatations in 29 patients with benign stenoses of the oesophagus of varying origin and in one patient with malignant stenosis 109 operations were made in 5 patients with corrosive stenoses. Three of these five patients suffered from double stenosis. For dilatation balloon catheters of Cook Co. were used. In the whole group only once a complication was observed, in the group of patients with corrosive stenoses no complication developed.</p>","PeriodicalId":75692,"journal":{"name":"Ceskoslovenska otolaryngologie","volume":"39 1","pages":"26-32"},"PeriodicalIF":0.0000,"publicationDate":"1990-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceskoslovenska otolaryngologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

During the period between October 1985 and the end of March 1988 from a total number of 269 dilatations in 29 patients with benign stenoses of the oesophagus of varying origin and in one patient with malignant stenosis 109 operations were made in 5 patients with corrosive stenoses. Three of these five patients suffered from double stenosis. For dilatation balloon catheters of Cook Co. were used. In the whole group only once a complication was observed, in the group of patients with corrosive stenoses no complication developed.

球囊导管在食管腐蚀性狭窄扩张中的应用
在1985年10月至1988年3月底期间,对29例不同来源的良性食管狭窄患者和1例恶性食管狭窄患者进行了269次扩张手术,对5例腐蚀性食管狭窄患者进行了109次手术。这5名患者中有3名患有双侧狭窄。扩张使用库克公司的球囊导管。全组仅1例出现并发症,腐蚀性狭窄组无并发症发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信