Performance Analysis of Semi-refined Digital Forearm Modeling and Simplified Forearm Model in Electromagnetic Simulation

Q3 Engineering
Jiangming Kuang, Yuping Qin, Shuang Zhang
{"title":"Performance Analysis of Semi-refined Digital Forearm Modeling and Simplified Forearm Model in Electromagnetic Simulation","authors":"Jiangming Kuang, Yuping Qin, Shuang Zhang","doi":"10.2174/0118722121269816230926120046","DOIUrl":null,"url":null,"abstract":"Objective: The objective of this study is to analyze the performance difference between simplified and digital models based on medical images. Methods: According to the characteristics of human anatomy, the finite element simulation software COMSOL Multiphysics 5.5 was employed to construct a simplified arm model using cylinders and a digital arm model based on Chinese digital human regarding electroacupuncture therapy as an example. A comparative analysis was then performed considering three aspects: mesh number, potential distribution, and resource consumption. Results: Through analysis, the digital arm model based on Chinese digital human requires significantly more mesh cells than the simplified arm model in mesh generation. Meanwhile, because the digital arm model based on the Chinese digital human fully expresses the nonuniformity of the tissue distribution in a real human body, its signal distribution in its interior is also relatively scattered, and the coupling potential slightly differs at the electrode vertex with the smallest change. In addition, the digital arm model has much higher resource consumption and computer hardware resource requirements compared with the simplified arm model. Conclusion: As a result, the digital model based on the Chinese digital human can more fully express the tissue distribution and electrical signal characteristics of a real human body. However, due to its high computational requirements, appropriate simplification can be selected to improve the computational efficiency of the model in practical applications.","PeriodicalId":40022,"journal":{"name":"Recent Patents on Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Patents on Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/0118722121269816230926120046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The objective of this study is to analyze the performance difference between simplified and digital models based on medical images. Methods: According to the characteristics of human anatomy, the finite element simulation software COMSOL Multiphysics 5.5 was employed to construct a simplified arm model using cylinders and a digital arm model based on Chinese digital human regarding electroacupuncture therapy as an example. A comparative analysis was then performed considering three aspects: mesh number, potential distribution, and resource consumption. Results: Through analysis, the digital arm model based on Chinese digital human requires significantly more mesh cells than the simplified arm model in mesh generation. Meanwhile, because the digital arm model based on the Chinese digital human fully expresses the nonuniformity of the tissue distribution in a real human body, its signal distribution in its interior is also relatively scattered, and the coupling potential slightly differs at the electrode vertex with the smallest change. In addition, the digital arm model has much higher resource consumption and computer hardware resource requirements compared with the simplified arm model. Conclusion: As a result, the digital model based on the Chinese digital human can more fully express the tissue distribution and electrical signal characteristics of a real human body. However, due to its high computational requirements, appropriate simplification can be selected to improve the computational efficiency of the model in practical applications.
半精细化数字前臂建模与简化前臂模型在电磁仿真中的性能分析
目的:本研究的目的是分析基于医学图像的简化模型和数字模型的性能差异。方法:根据人体解剖特点,采用有限元仿真软件COMSOL Multiphysics 5.5,以电针治疗为例,构建基于圆柱体的简化手臂模型和基于中国数字人体的数字手臂模型。然后从网格数、潜在分布和资源消耗三个方面进行比较分析。结果:通过分析,基于中文数字人体的数字臂模型在网格生成上需要的网格单元数明显多于简化臂模型。同时,由于基于中国数字人体的数字手臂模型充分表达了真实人体组织分布的非均匀性,因此其内部的信号分布也相对分散,在电极顶点处耦合电位略有差异,变化最小。此外,与简化臂模型相比,数字臂模型的资源消耗和计算机硬件资源要求要高得多。结论:基于中国数字人体的数字模型能够更全面地表达真实人体的组织分布和电信号特征。但由于计算量要求高,在实际应用中可以选择适当的简化,以提高模型的计算效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Recent Patents on Engineering
Recent Patents on Engineering Engineering-Engineering (all)
CiteScore
1.40
自引率
0.00%
发文量
100
期刊介绍: Recent Patents on Engineering publishes review articles by experts on recent patents in the major fields of engineering. A selection of important and recent patents on engineering is also included in the journal. The journal is essential reading for all researchers involved in engineering sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信