MRI Modeling for 3D Printed Fabrication of Nasoalveolar Molding Appliance in Patients With Cleft Lip and Palate

Chelsea L. Wehr, Austin Lignieres, Chioma G. Obinero, Alfredo Cepeda, Antonio Cardenas, F. Kurtis Kasper, Bhavini Acharya, Eliana Bonfante-Mejia, Roy Riascos-Castaneda, Rajan Patel, Brett T. Chiquet, Matthew R. Greives
{"title":"MRI Modeling for 3D Printed Fabrication of Nasoalveolar Molding Appliance in Patients With Cleft Lip and Palate","authors":"Chelsea L. Wehr, Austin Lignieres, Chioma G. Obinero, Alfredo Cepeda, Antonio Cardenas, F. Kurtis Kasper, Bhavini Acharya, Eliana Bonfante-Mejia, Roy Riascos-Castaneda, Rajan Patel, Brett T. Chiquet, Matthew R. Greives","doi":"10.1177/27325016231208381","DOIUrl":null,"url":null,"abstract":"Purpose: Present a novel technique for fabrication of nasoalveolar molding (NAM) appliances for neonates with cleft lip and palate (CLP) using magnetic resonance imaging (MRI). Study design: Proof-of-concept study. Setting/Participants: One patient with unilateral CLP was recruited for participation in this study at our institution. Interventions: This study employed 2 different methods for creating a NAM appliance, which is used in patients with CLP to improve anatomic positioning of the orofacial cleft in preparation for primary cheiloplasty. The patient underwent intraoral impression for traditional fabrication of a NAM appliance (PMMA-NAM) and also MRI of the face for digital fabrication of a NAM appliance (CAD-NAM). The 2 appliances were then compared using landmarks for measurements. Primary Outcome: Landmark measurements on NAM appliances; Clinical interchangeability of NAM appliances. Results: There was a statistically significant difference in the external arch width between the CAD-NAM and the PMMA-NAM. All other NAM measurements were statistically similar. Additionally, there was clinical success in the interchangeable fit of both appliances on both models. Conclusions: This technique could potentially eliminate the need for creation of an intraoral impression, as well as the adverse events associated with this, in the fabrication of NAM appliances. Larger studies are necessary to further define the efficacy of this novel approach and generalizability to other patients with CLP.","PeriodicalId":93749,"journal":{"name":"FACE (Thousand Oaks, Calif.)","volume":"59 8","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"FACE (Thousand Oaks, Calif.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/27325016231208381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Present a novel technique for fabrication of nasoalveolar molding (NAM) appliances for neonates with cleft lip and palate (CLP) using magnetic resonance imaging (MRI). Study design: Proof-of-concept study. Setting/Participants: One patient with unilateral CLP was recruited for participation in this study at our institution. Interventions: This study employed 2 different methods for creating a NAM appliance, which is used in patients with CLP to improve anatomic positioning of the orofacial cleft in preparation for primary cheiloplasty. The patient underwent intraoral impression for traditional fabrication of a NAM appliance (PMMA-NAM) and also MRI of the face for digital fabrication of a NAM appliance (CAD-NAM). The 2 appliances were then compared using landmarks for measurements. Primary Outcome: Landmark measurements on NAM appliances; Clinical interchangeability of NAM appliances. Results: There was a statistically significant difference in the external arch width between the CAD-NAM and the PMMA-NAM. All other NAM measurements were statistically similar. Additionally, there was clinical success in the interchangeable fit of both appliances on both models. Conclusions: This technique could potentially eliminate the need for creation of an intraoral impression, as well as the adverse events associated with this, in the fabrication of NAM appliances. Larger studies are necessary to further define the efficacy of this novel approach and generalizability to other patients with CLP.
唇腭裂患者鼻牙槽成型器3D打印的MRI建模
目的:介绍一种利用磁共振成像(MRI)制作新生儿唇腭裂(CLP)鼻肺泡成型(NAM)矫治器的新技术。研究设计:概念验证研究。环境/参与者:我们机构招募了一名单侧CLP患者参加本研究。干预措施:本研究采用两种不同的方法制作NAM矫治器,用于CLP患者改善口面裂的解剖定位,为初次唇腭裂成形术做准备。患者接受了口腔内印模,用于传统的NAM矫治器制作(PMMA-NAM),并进行了面部MRI,用于数字制作NAM矫治器(CAD-NAM)。然后用地标测量比较这两种器具。主要结果:不结盟运动器具的里程碑测量;NAM器械的临床互换性。结果:CAD-NAM与PMMA-NAM的外弓宽度差异有统计学意义。所有其他NAM测量在统计上是相似的。此外,在两种型号上的两种器具的可互换配合方面取得了临床成功。结论:该技术可以潜在地消除制造口腔内印模的需要,以及在制造NAM矫治器时与之相关的不良事件。需要更大规模的研究来进一步确定这种新方法的疗效和推广到其他CLP患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信