Evaluation of X-Ray Doses in Pediatrics Multislice Computed Tomography

IF 1.4 4区 医学 Q4 ENVIRONMENTAL SCIENCES
Hassan Khajmi, Fatima Ait Nouh, Abdessamad Tounsi, Rodouan Touti
{"title":"Evaluation of X-Ray Doses in Pediatrics Multislice Computed Tomography","authors":"Hassan Khajmi, Fatima Ait Nouh, Abdessamad Tounsi, Rodouan Touti","doi":"10.1051/radiopro/2023029","DOIUrl":null,"url":null,"abstract":"The present paper aims to estimate the doses delivered to children during a multislice computed tomography examination at the Mohammed VI University Hospital Center of Marrakech in Morocco and to compare our values with the dosimetric data the others countries. Method of Study. This study was conducted from 1st January 2020 to 1stMay 2020 at the pediatrics Computed Tomography unit in radiology service of Mother and Child Hospital of Marrakech –Safi region Morocco. Tube voltage, the Volume Computed Tomography dose index CTDIvol and the Dose-Length-Product DLP, current tube in milliamper seconds mAs), rotation time in seconds, slice thickness and collimation were collected by dosimetric sheet for three age groups of young with age ranged between 1 year- 4 year (AG1y5y), 5 year-10 year (AG5y10y) and 10 year-15 year (AG10y15y) The CT examinations studied are CTs of the Head, Chest and Abdominal-Pelvis. Results. For the studied age’s groups of children, 67 % of Computed Tomography exams were performed with a value of tube voltage 120 kV and 33% with a value of 110 kV. A comparison of CTDIvol and the Dose-Length-Product DLP For the three age groups AG1y5y, AG5y10y and AG10y15y of younger’s considered with other studies revealed that our DLP values from head CT are less than the recommended standards registered in literatures However, those of the Abdomen Pelvis and Chest CT are significantly higher than the Belgium and Germany diagnostic references levels. Furthermore the effective dose distributions ED were: 37, 2.2 and 1.2 mSv for head CT, 5.60, 3.2 and 3.1 mSv for chest CT protocol and 3.2, 88 and 8 mSv for abdominal-pelvis CT protocol. Conclusion. This study showed that our mean values of DLP for head CT are less than other National Diagnostic Dose Reference Levels. However, those of the Abdomen Pelvis and Chest CT are significantly higher than the diagnostic references levels in Belgium and Germany.","PeriodicalId":21009,"journal":{"name":"Radioprotection","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radioprotection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/radiopro/2023029","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The present paper aims to estimate the doses delivered to children during a multislice computed tomography examination at the Mohammed VI University Hospital Center of Marrakech in Morocco and to compare our values with the dosimetric data the others countries. Method of Study. This study was conducted from 1st January 2020 to 1stMay 2020 at the pediatrics Computed Tomography unit in radiology service of Mother and Child Hospital of Marrakech –Safi region Morocco. Tube voltage, the Volume Computed Tomography dose index CTDIvol and the Dose-Length-Product DLP, current tube in milliamper seconds mAs), rotation time in seconds, slice thickness and collimation were collected by dosimetric sheet for three age groups of young with age ranged between 1 year- 4 year (AG1y5y), 5 year-10 year (AG5y10y) and 10 year-15 year (AG10y15y) The CT examinations studied are CTs of the Head, Chest and Abdominal-Pelvis. Results. For the studied age’s groups of children, 67 % of Computed Tomography exams were performed with a value of tube voltage 120 kV and 33% with a value of 110 kV. A comparison of CTDIvol and the Dose-Length-Product DLP For the three age groups AG1y5y, AG5y10y and AG10y15y of younger’s considered with other studies revealed that our DLP values from head CT are less than the recommended standards registered in literatures However, those of the Abdomen Pelvis and Chest CT are significantly higher than the Belgium and Germany diagnostic references levels. Furthermore the effective dose distributions ED were: 37, 2.2 and 1.2 mSv for head CT, 5.60, 3.2 and 3.1 mSv for chest CT protocol and 3.2, 88 and 8 mSv for abdominal-pelvis CT protocol. Conclusion. This study showed that our mean values of DLP for head CT are less than other National Diagnostic Dose Reference Levels. However, those of the Abdomen Pelvis and Chest CT are significantly higher than the diagnostic references levels in Belgium and Germany.
儿科多层计算机断层扫描x射线剂量的评价
本论文旨在估计在摩洛哥马拉喀什穆罕默德六世大学医院中心进行多层计算机断层扫描检查时给予儿童的剂量,并将我们的值与其他国家的剂量学数据进行比较。研究方法。本研究于2020年1月1日至2020年5月1日在马拉喀什-萨菲地区摩洛哥妇幼医院放射科儿科计算机断层摄影科进行。通过剂量计片收集了3组年龄在1 - 4岁(AG1y5y)、5 -10岁(AG5y10y)和10 -15岁(AG10y15y)的青少年的管电压、体积计算机断层扫描剂量指数CTDIvol和剂量-长度-积DLP、电流管(毫安秒mAs)、旋转时间(秒)、切片厚度和准直所研究的CT检查为头部、胸部和腹部-骨盆CT。结果。在研究年龄组的儿童中,67%的计算机断层扫描检查的管电压值为120千伏,33%的管电压值为110千伏。通过比较AG1y5y、AG5y10y和AG10y15y三个年龄组的CTDIvol和剂量-长度-积DLP与其他研究发现,我们头部CT的DLP值低于文献中推荐的标准,而腹部骨盆和胸部CT的DLP值明显高于比利时和德国的诊断参考水平。此外,有效剂量分布ED分别为:头部CT为37、2.2和1.2 mSv,胸部CT为5.60、3.2和3.1 mSv,腹部-骨盆CT为3.2、88和8 mSv。结论。本研究显示,我们的头部CT DLP平均值低于其他国家诊断剂量参考水平。然而,腹部骨盆和胸部CT的诊断参考水平明显高于比利时和德国的诊断参考水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radioprotection
Radioprotection ENVIRONMENTAL SCIENCES-PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
CiteScore
3.30
自引率
54.50%
发文量
35
审稿时长
>12 weeks
期刊介绍: Radioprotection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes (theoretical and practical aspects): dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信