[Complications of the postoperative use of lumbar epidural catheters in place for surgery].

IF 1.9 Q2 POLITICAL SCIENCE
Regional-Anaesthesie Pub Date : 1990-03-01
M G Rockemann, W Seeling
{"title":"[Complications of the postoperative use of lumbar epidural catheters in place for surgery].","authors":"M G Rockemann,&nbsp;W Seeling","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two cases of secondary subarachnoidal dislocation of lumbar epidural catheters are reported. The first catheter was placed, tested, and injected with 20 ml local anesthetic in order to achieve intraoperative anesthesia up to the T4 level. On the 2nd postoperative day the test dose produced paralysis of the lower extremities; liquor now could be aspirated. The second catheter had been introduced into the epidural space immediately after injection of 15 ml local anesthetic through the needle. Use of this catheter for postoperative analgesia led to total spinal anesthesia in spite of negative aspiration and test dose prior to injection of 7 ml local anesthetic. Implications of these two cases concerning placement procedures and monitoring during reuse of catheters placed some time before are discussed.</p>","PeriodicalId":77604,"journal":{"name":"Regional-Anaesthesie","volume":"13 2","pages":"36-8"},"PeriodicalIF":1.9000,"publicationDate":"1990-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Regional-Anaesthesie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"POLITICAL SCIENCE","Score":null,"Total":0}
引用次数: 0

Abstract

Two cases of secondary subarachnoidal dislocation of lumbar epidural catheters are reported. The first catheter was placed, tested, and injected with 20 ml local anesthetic in order to achieve intraoperative anesthesia up to the T4 level. On the 2nd postoperative day the test dose produced paralysis of the lower extremities; liquor now could be aspirated. The second catheter had been introduced into the epidural space immediately after injection of 15 ml local anesthetic through the needle. Use of this catheter for postoperative analgesia led to total spinal anesthesia in spite of negative aspiration and test dose prior to injection of 7 ml local anesthetic. Implications of these two cases concerning placement procedures and monitoring during reuse of catheters placed some time before are discussed.

[术后使用硬膜外置管进行手术的并发症]。
本文报告2例腰椎硬膜外导管继发性蛛网膜下脱位。放置第一根导管,检测后注射20ml局麻药,使术中麻醉达到T4水平。术后第2天试验剂量产生下肢瘫痪;酒现在可以吸入了。第二根导管经针入局麻药15ml后立即插入硬膜外腔。使用该导管进行术后镇痛导致全脊髓麻醉,尽管在注射7 ml局麻药之前有阴性抽吸和试验剂量。本文讨论了这两种情况对置管程序的影响,以及在置管前一段时间重新使用期间的监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信