Breathing rate estimation from a non-contact biosensor using an adaptive IIR notch filter

T. Ballal, R. Shouldice, C. Heneghan, A. Zhu
{"title":"Breathing rate estimation from a non-contact biosensor using an adaptive IIR notch filter","authors":"T. Ballal, R. Shouldice, C. Heneghan, A. Zhu","doi":"10.1109/BIOWIRELESS.2012.6172727","DOIUrl":null,"url":null,"abstract":"In this paper, a non-contact method for human breathing rate estimation is discussed. The method utilises SleepMinder technology, which implements a radio-frequency Doppler radar system to capture physiological movements of the body in the form of phase modulation. To determine the breathing rate, the signals are down-converted and the baseband signals are processed. Previously reported methods used the conventional periodogram approach to estimate the breathing rate. A downside of the periodogram method is its limited capability in capturing respiration dynamics. The adaptive notch filter approach, discussed herein, provides a better respiration rate tracking performance than the periodogram approach, as demonstrated by the experimental results presented in this paper.","PeriodicalId":297010,"journal":{"name":"2012 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOWIRELESS.2012.6172727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

In this paper, a non-contact method for human breathing rate estimation is discussed. The method utilises SleepMinder technology, which implements a radio-frequency Doppler radar system to capture physiological movements of the body in the form of phase modulation. To determine the breathing rate, the signals are down-converted and the baseband signals are processed. Previously reported methods used the conventional periodogram approach to estimate the breathing rate. A downside of the periodogram method is its limited capability in capturing respiration dynamics. The adaptive notch filter approach, discussed herein, provides a better respiration rate tracking performance than the periodogram approach, as demonstrated by the experimental results presented in this paper.
基于自适应IIR陷波滤波器的非接触式生物传感器呼吸频率估计
本文讨论了一种用于人体呼吸频率估计的非接触方法。该方法利用SleepMinder技术,该技术采用射频多普勒雷达系统,以相位调制的形式捕捉身体的生理运动。为了确定呼吸速率,对信号进行下转换,并对基带信号进行处理。以前报道的方法使用传统的周期图方法来估计呼吸频率。周期图方法的一个缺点是它在捕捉呼吸动力学方面的能力有限。本文的实验结果表明,本文讨论的自适应陷波滤波器方法比周期图方法提供了更好的呼吸速率跟踪性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信