{"title":"A current controlled near unity power factor three-phase PWM buck rectifier without passive damping requirements","authors":"N. Zargari, D. Raonic","doi":"10.1109/CCECE.1995.526594","DOIUrl":null,"url":null,"abstract":"Three-phase current source PWM rectifier (also known as three-phase buck rectifier) is often used as the front-end in utility interfaced systems. An input LC filter is required to suppress the current harmonics injected into AC mains. The input filter affects the input displacement factor (IDF) of the system, which varies with the rectifier operating point and may result in unacceptable low values. In this paper, closed-loop control of the input line currents is proposed to achieve near unity IDF independent of the load conditions. The current reference template is generated from the filter capacitor voltages, the need for damping resistors is eliminated and efficiency is increased. The output DC current is regulated by varying the amplitudes of the current references. The proposed scheme features good steady state results, fast transient response and higher efficiency. The paper includes analysis, a design example and simulation results for steady state and transient conditions.","PeriodicalId":158581,"journal":{"name":"Proceedings 1995 Canadian Conference on Electrical and Computer Engineering","volume":"107 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 1995 Canadian Conference on Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCECE.1995.526594","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Three-phase current source PWM rectifier (also known as three-phase buck rectifier) is often used as the front-end in utility interfaced systems. An input LC filter is required to suppress the current harmonics injected into AC mains. The input filter affects the input displacement factor (IDF) of the system, which varies with the rectifier operating point and may result in unacceptable low values. In this paper, closed-loop control of the input line currents is proposed to achieve near unity IDF independent of the load conditions. The current reference template is generated from the filter capacitor voltages, the need for damping resistors is eliminated and efficiency is increased. The output DC current is regulated by varying the amplitudes of the current references. The proposed scheme features good steady state results, fast transient response and higher efficiency. The paper includes analysis, a design example and simulation results for steady state and transient conditions.
一种电流控制的近单位功率因数三相PWM降压整流器,无被动阻尼要求
三相电流源PWM整流器(又称三相降压整流器)常被用作公用事业接口系统的前端。输入LC滤波器需要抑制注入交流电源的电流谐波。输入滤波器影响系统的输入位移因子(IDF),它随整流器工作点的变化而变化,可能导致不可接受的低值。本文提出了对输入线电流进行闭环控制,以实现不受负载条件影响的近统一IDF。电流参考模板由滤波电容电压产生,消除了对阻尼电阻的需求,提高了效率。输出直流电流是通过改变电流基准的幅值来调节的。该方案具有稳态效果好、瞬态响应快、效率高等特点。文中包括稳态和暂态工况的分析、设计实例和仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信