Effect of Number and Position of Rotational Friction Dampers on Seismic Response of Steel Frame

I. Oance, S. Gelmambet
{"title":"Effect of Number and Position of Rotational Friction Dampers on Seismic Response of Steel Frame","authors":"I. Oance, S. Gelmambet","doi":"10.2478/ouacsce-2019-0011","DOIUrl":null,"url":null,"abstract":"Abstract This paper deals with effect of number and position of friction dampers on seismic response of 2D steel frame. For the present study four structures with six storeys are subjected to a time history analysis. For each story are using two, four and six friction dampers with different positions keeping slip load and stiffness constant. To study the effect of number and position of dampers in structures, are analysed the time period, top roof displacement, maximum base shear and percentage energy dissipated in accordance with energy induced in the frame. The results indicate that number and placement of damper affects the structural response. A large number of dampers do not always lead to best benefit in terms of energy dissipation.","PeriodicalId":345086,"journal":{"name":"Ovidius University Annals of Constanta - Series Civil Engineering","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ovidius University Annals of Constanta - Series Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ouacsce-2019-0011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract This paper deals with effect of number and position of friction dampers on seismic response of 2D steel frame. For the present study four structures with six storeys are subjected to a time history analysis. For each story are using two, four and six friction dampers with different positions keeping slip load and stiffness constant. To study the effect of number and position of dampers in structures, are analysed the time period, top roof displacement, maximum base shear and percentage energy dissipated in accordance with energy induced in the frame. The results indicate that number and placement of damper affects the structural response. A large number of dampers do not always lead to best benefit in terms of energy dissipation.
转动摩擦阻尼器数目和位置对钢框架地震反应的影响
摘要本文研究了摩擦阻尼器数目和位置对二维钢框架地震反应的影响。在本研究中,对四个六层结构进行了时程分析。每层分别使用2个、4个和6个不同位置的摩擦阻尼器,保持滑移载荷和刚度不变。为了研究减振器数目和位置对结构的影响,分析了减振器作用时间、顶板位移、最大基底剪力和耗能百分比。结果表明,阻尼器的数量和位置对结构响应有影响。大量的阻尼器并不总是在能量耗散方面带来最佳效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书