Analysis of the mobile phone effect on the heart rate variability by the calculation of correlation dimension

D. Yilmaz, M. Yıldız
{"title":"Analysis of the mobile phone effect on the heart rate variability by the calculation of correlation dimension","authors":"D. Yilmaz, M. Yıldız","doi":"10.1109/BIYOMUT.2009.5130290","DOIUrl":null,"url":null,"abstract":"In this work, the effect of the electromagnetic radiation generated by mobile phone, on the heart rate variability (HRV) has been investigated using correlation dimension calculation which is a nonlinear analysis method. The 17 volunteer subjects participated to our work and the experiment is designed as three periods and each period have 7 minutes. The electrocardiogram (ECG) signals were recorded from volunteers who are in the sitting position between the base station and mobile phone and mobile phone attached to the right ear of the subject by a bone. The mobile phone is continuously called by another mobile phone at the second period for 9 subjects and at the third period for 8 subjects, randomly. Mobile phone was open and standby condition, at the other periods. The HRV signals were obtained from ECG signals and correlation dimension analysis has been performed. The student-t test was applied to the correlation dimension values calculated from mobile phone calling and standby conditions. The correlation dimension that belongs to mobile phone calling condition is found higher than mobile phone standby condition (p≪0.05). The correlation dimension gives the minimum number of independent variables necessary to generate the system dynamics. The results show that the number of variables managed to the cardiovascular system behavior increase by reason of electromagnetic radiation generated by mobile phone.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 14th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2009.5130290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this work, the effect of the electromagnetic radiation generated by mobile phone, on the heart rate variability (HRV) has been investigated using correlation dimension calculation which is a nonlinear analysis method. The 17 volunteer subjects participated to our work and the experiment is designed as three periods and each period have 7 minutes. The electrocardiogram (ECG) signals were recorded from volunteers who are in the sitting position between the base station and mobile phone and mobile phone attached to the right ear of the subject by a bone. The mobile phone is continuously called by another mobile phone at the second period for 9 subjects and at the third period for 8 subjects, randomly. Mobile phone was open and standby condition, at the other periods. The HRV signals were obtained from ECG signals and correlation dimension analysis has been performed. The student-t test was applied to the correlation dimension values calculated from mobile phone calling and standby conditions. The correlation dimension that belongs to mobile phone calling condition is found higher than mobile phone standby condition (p≪0.05). The correlation dimension gives the minimum number of independent variables necessary to generate the system dynamics. The results show that the number of variables managed to the cardiovascular system behavior increase by reason of electromagnetic radiation generated by mobile phone.
通过计算相关维数分析手机对心率变异性的影响
本文采用相关维数计算这一非线性分析方法,研究了手机电磁辐射对心率变异性的影响。17名志愿者参与了我们的工作,实验分为三个时间段,每个时间段7分钟。志愿者坐在基站和手机之间,用一根骨头把手机固定在他们的右耳上,记录下他们的心电图信号。9名受试者在第二期、8名受试者在第三期随机由另一部手机连续拨打该手机。手机处于打开和待机状态,在其他时间段。从心电信号中提取HRV信号,并进行相关维数分析。对手机通话与待机状态计算的相关维度值进行student-t检验。与手机通话状态相关的维度高于手机待机状态(p≪0.05)。相关维数给出了产生系统动力学所需的最小自变量数。结果表明,由于手机产生的电磁辐射,心血管系统行为的变量数量增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信