N. Leboeuf, T. Boileau, B. Nahid-Mobarakeh, F. Meibody-Tabar
{"title":"Fault Detection in a Current Controlled PM Drive Using Back-EMF Estimation and Residual Analysis","authors":"N. Leboeuf, T. Boileau, B. Nahid-Mobarakeh, F. Meibody-Tabar","doi":"10.1109/IAS.2010.5616894","DOIUrl":null,"url":null,"abstract":"In this paper, a new technique for on-line detecting inter-turn stator winding fault in Permanent Magnet Synchronous Machine (PMSM) is presented. It is based on a residual analysis improved by adding a back-EMF waveform estimation system which allows identifying real back-EMF frequency components of the healthy machine. Then, a simple current residual monitoring permits us to detect the fault and its severity. Simulations and experimentations validate the proposed method and its efficiency.","PeriodicalId":317643,"journal":{"name":"2010 IEEE Industry Applications Society Annual Meeting","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2010.5616894","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
In this paper, a new technique for on-line detecting inter-turn stator winding fault in Permanent Magnet Synchronous Machine (PMSM) is presented. It is based on a residual analysis improved by adding a back-EMF waveform estimation system which allows identifying real back-EMF frequency components of the healthy machine. Then, a simple current residual monitoring permits us to detect the fault and its severity. Simulations and experimentations validate the proposed method and its efficiency.