Innovative Design for Monitoring of Neonates Using Reflectance Pulse Oximeter

D. Potuzakova, Wei Chen, Sidarto Bambang-Oetomo, L. Feijs
{"title":"Innovative Design for Monitoring of Neonates Using Reflectance Pulse Oximeter","authors":"D. Potuzakova, Wei Chen, Sidarto Bambang-Oetomo, L. Feijs","doi":"10.1109/IE.2011.12","DOIUrl":null,"url":null,"abstract":"Critically ill prematurely born babies admitted at the neonatal intensive care unit (NICU) have to be monitored constantly. The saturation of the peripheral oxygen (SPO2) is one of the crucial monitoring parameters on these babies. It is necessary that these fragile neonates feel most comfortable as possible during the monitoring. The current solutions for these SPO2 oximeters can be uncomfortable for use and hampers parent-child interaction. In this paper we propose an innovative solution for reflectance pulse oximeter based on Near Infrared Spectroscopy (NIRS) techniques that will lead into more comfortable use in a long term monitoring. Prototypes with the reflectance sensors embedded in soft foam and fabric materials are built to enhance a comfortable non-invasive yet reliable monitoring. These monitoring units give the opportunity of integration into a snuggle and mattress where the baby lays on most of the time. In this paper we report the integration of the prototype monitoring units into a snuggle. To evaluate the comfort as well as performance of the final prototype, we first conduct tests on adults. The prototype monitoring units are tested on various body locations of adult participants. Signal quality on different body locations is reported and questionnaires for comfort assessment are analyzed. Experiments on the premature babies will be carried out at NICU of Máxima Medical Centre (MMC) in Veldhoven, the Netherlands.","PeriodicalId":207140,"journal":{"name":"2011 Seventh International Conference on Intelligent Environments","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Seventh International Conference on Intelligent Environments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IE.2011.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Critically ill prematurely born babies admitted at the neonatal intensive care unit (NICU) have to be monitored constantly. The saturation of the peripheral oxygen (SPO2) is one of the crucial monitoring parameters on these babies. It is necessary that these fragile neonates feel most comfortable as possible during the monitoring. The current solutions for these SPO2 oximeters can be uncomfortable for use and hampers parent-child interaction. In this paper we propose an innovative solution for reflectance pulse oximeter based on Near Infrared Spectroscopy (NIRS) techniques that will lead into more comfortable use in a long term monitoring. Prototypes with the reflectance sensors embedded in soft foam and fabric materials are built to enhance a comfortable non-invasive yet reliable monitoring. These monitoring units give the opportunity of integration into a snuggle and mattress where the baby lays on most of the time. In this paper we report the integration of the prototype monitoring units into a snuggle. To evaluate the comfort as well as performance of the final prototype, we first conduct tests on adults. The prototype monitoring units are tested on various body locations of adult participants. Signal quality on different body locations is reported and questionnaires for comfort assessment are analyzed. Experiments on the premature babies will be carried out at NICU of Máxima Medical Centre (MMC) in Veldhoven, the Netherlands.
利用反射式脉搏血氧仪监测新生儿的创新设计
新生儿重症监护病房(NICU)收治的危重早产儿必须不断监测。外周氧饱和度(SPO2)是这些婴儿的重要监测参数之一。在监测过程中,有必要让这些脆弱的新生儿尽可能感到舒适。目前这些SPO2血氧计的解决方案使用起来不舒服,妨碍了亲子互动。在本文中,我们提出了一种基于近红外光谱(NIRS)技术的反射式脉搏血氧仪的创新解决方案,该方案将在长期监测中更加舒适地使用。在柔软的泡沫和织物材料中嵌入反射传感器的原型可以增强舒适的非侵入性但可靠的监测。这些监控单元提供了集成到一个依偎和床垫的机会,婴儿躺在那里的大部分时间。在本文中,我们报告了原型监测单元集成到一个依偎。为了评估最终原型的舒适性和性能,我们首先对成年人进行了测试。原型监测单元在成年参与者的不同身体部位进行了测试。报告了不同身体位置的信号质量,并分析了舒适度评估问卷。这些早产儿的实验将在荷兰费尔德霍芬Máxima医学中心(MMC)的新生儿重症监护室进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信