{"title":"Study of different grades of CRGO core material for evaluation of power factor","authors":"G. K. Kumar, R. Kumar","doi":"10.1109/CATCON47128.2019.CN00020","DOIUrl":null,"url":null,"abstract":"Electrical steel is significant material and used as core in the manufacture of electrical devices for power and distribution transformers. The magnetic properties of these steels need to be precisely estimated in order to design an accurate electrical device. Deterioration of the Cold Rolled Grain Oriented (CRGO) electrical steels can severely influence the electrical and magnetic properties and thereby the performance of the devices in which they are integrated. A study was conducted on 20 nos of different thickness grades of CRGO electrical steel of primary, non-prime grade CRGO steel and used core material (removed) from transformer. The thickness grades used for the experimental work are 5 nos. of 0.23 grade, 9 nos. of 0.27 grade, 4 nos. of 0.30 grade and 2 nos. of 0.35 grades. The magnetic properties are evaluated such as core loss, apparent power and power factor was calculated. The power factor values for the prime grades are from 0.75 to 0.4, but where as non-prime and used core steel values are below 0.3.","PeriodicalId":183797,"journal":{"name":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON47128.2019.CN00020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electrical steel is significant material and used as core in the manufacture of electrical devices for power and distribution transformers. The magnetic properties of these steels need to be precisely estimated in order to design an accurate electrical device. Deterioration of the Cold Rolled Grain Oriented (CRGO) electrical steels can severely influence the electrical and magnetic properties and thereby the performance of the devices in which they are integrated. A study was conducted on 20 nos of different thickness grades of CRGO electrical steel of primary, non-prime grade CRGO steel and used core material (removed) from transformer. The thickness grades used for the experimental work are 5 nos. of 0.23 grade, 9 nos. of 0.27 grade, 4 nos. of 0.30 grade and 2 nos. of 0.35 grades. The magnetic properties are evaluated such as core loss, apparent power and power factor was calculated. The power factor values for the prime grades are from 0.75 to 0.4, but where as non-prime and used core steel values are below 0.3.
研究不同牌号的CRGO芯材对功率因数的评价
电工钢是制造电力变压器和配电变压器用电气设备的重要材料。为了设计精确的电气装置,需要精确地估计这些钢的磁性能。冷轧晶粒取向(CRGO)电工钢的劣化会严重影响其电气和磁性能,从而影响其集成设备的性能。对20号不同厚度等级的CRGO电工钢进行了试验研究,其中包括初级CRGO钢、非初级CRGO钢和从变压器中取出的旧铁芯材料。用于实验工作的厚度等级为0.23级5个,0.27级9个,0.30级4个,0.35级2个。评估了磁芯损耗、视在功率和功率因数等磁性能。主要等级的功率因数值为0.75至0.4,但非主要等级和使用的核心钢的功率因数值低于0.3。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信