{"title":"Coordination of an SVC with a ULTC reserving compensation margin for emergency control","authors":"K. Son, K. S. Moon, S.K. Lee, J. Park","doi":"10.1109/PICA.1999.779517","DOIUrl":null,"url":null,"abstract":"This paper proposes a coordinated control scheme of an SVC (static VAr compensator) and a ULTC (under load tap changer) of the distribution substation to get larger operating margin of SVC for emergency control. The conventional method can cause the lack of operating margin of SVC in some condition. It however, is important to secure an operating margin for emergency. In the proposed coordinated control system, SVC controls the voltage and ULTC responds to the SVC compensation value based on the relation between SVC compensation and ULTC tap position. In order to reserve the operating margin of the SVC, the time delay of ULTC is adaptively changed according to the operating condition of the SVC. Numerical simulations verify that the proposed system could increase the operating margin of SVC while improving the quality of load voltage.","PeriodicalId":113146,"journal":{"name":"Proceedings of the 21st International Conference on Power Industry Computer Applications. Connecting Utilities. PICA 99. To the Millennium and Beyond (Cat. No.99CH36351)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"49","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 21st International Conference on Power Industry Computer Applications. Connecting Utilities. PICA 99. To the Millennium and Beyond (Cat. No.99CH36351)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PICA.1999.779517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 49
Abstract
This paper proposes a coordinated control scheme of an SVC (static VAr compensator) and a ULTC (under load tap changer) of the distribution substation to get larger operating margin of SVC for emergency control. The conventional method can cause the lack of operating margin of SVC in some condition. It however, is important to secure an operating margin for emergency. In the proposed coordinated control system, SVC controls the voltage and ULTC responds to the SVC compensation value based on the relation between SVC compensation and ULTC tap position. In order to reserve the operating margin of the SVC, the time delay of ULTC is adaptively changed according to the operating condition of the SVC. Numerical simulations verify that the proposed system could increase the operating margin of SVC while improving the quality of load voltage.