{"title":"Remaining Service Life Struktur Conveyor A pada Tambang Batubara PT XYZ di Kabupaten Tanah Laut, Provinsi Kalimantan Selatan","authors":"Rihhadatul Aisyi Alfafa, Elfida Moralista, Zaenal","doi":"10.29313/bcsme.v2i2.3269","DOIUrl":null,"url":null,"abstract":"Abstract. Coal transportation at PT XYZ in Tanah Laut Regency, South Kalimantan Province uses a transportation equipment such conveyors. The conveyor structure is made of low carbon steel which is susceptible to corrosion. Corrosion that occurs in the conveyor structure is caused by damage to the coating due to contact with the environment. Therefore this research was carried out on the conveyor structure with the aim of knowing the type of corrosion and corrosion control methods applied to the conveyor structure. The measurement methodology used on the conveyor structure with a length of 90 meters and 25 test points is based on thickness reduction of the conveyor structure using Ultrasonic Thickness Gauge TT 130. This measurement obtain information about the actual thickness of the conveyor structure which then becomes the input for calculating the Corrosion Rate and Remaining Life of the conveyor structure.The research conditions from 2015-2019 showed rainfall of 206.78 mm/year, air temperature of 28.09OC, and humidity of 78.78%. These environmental conditions will cause corrosion when interacting with the conveyor structure. Corrosion that occurs on the conveyor structure is a type of uniform corrosion. Corrosion control is carried out on the conveyor structure by using the three layers system coating method. This system consists of primary coating using Seaguard 5000, intermediate coating using Sherglass FF, and top coating using Aliphatic acrylic modified polyurethane. \nAbstrak. Pengangkutan batubara di PT XYZ di Kabupaten Tanah Laut, Provinsi Kalimantan Selatan menggunakan alat angkut berupa conveyor. Struktur conveyor yang digunakan berbahan dasar baja karbon (low carbon steel) yang rentan terjadi korosi. Korosi yang terjadi pada struktur conveyor disebabkan karena adanya kerusakan pada coating akibat kontak dengan lingkungan. Oleh karena itu dilakukanlah penelitian pada struktur conveyor dengan tujuan untuk mengetahui jenis korosi dan metode pengendalian korosi yang diaplikasikan pada struktur conveyor. Metodologi pengukuran yang digunakan pada struktur conveyor sepanjang 90 meter dan 25 test point ini berdasarkan pengurangan ketebalan struktur conveyor menggunakan Ultrasonic Thickness Gauge TT 130. Pengukuran ini membantu dalam mengetahui tebal aktual struktur conveyor yang selanjutnya menjadi input untuk perhitungan Corrosion Rate dan Remaining Service Life struktur conveyor. Kondisi penelitian dari tahun 2015-2019 menunjukkan curah hujan sebesar 206,78 mm/tahun, temperatur udara sebesar 28,09OC, dan kelembapan udara sebesar 78,78%. Kondisi lingkungan ini akan menyebabkan korosi ketika berinteraksi dengan struktur conveyor. Korosi yang terjadi pada struktur conveyor merupakan jenis korosi merata. Metode pengendalian korosi yang diaplikasikan pada struktur conveyor adalah metode coating three layers system. Sistem ini terdiri dari primer coating menggunakan Seaguard 5000, intermediate coating menggunakan Sherglass FF, dan top coating menggunakan Aliphatic acrylic modified polyurethane.","PeriodicalId":187584,"journal":{"name":"Bandung Conference Series: Mining Engineering","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bandung Conference Series: Mining Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29313/bcsme.v2i2.3269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract. Coal transportation at PT XYZ in Tanah Laut Regency, South Kalimantan Province uses a transportation equipment such conveyors. The conveyor structure is made of low carbon steel which is susceptible to corrosion. Corrosion that occurs in the conveyor structure is caused by damage to the coating due to contact with the environment. Therefore this research was carried out on the conveyor structure with the aim of knowing the type of corrosion and corrosion control methods applied to the conveyor structure. The measurement methodology used on the conveyor structure with a length of 90 meters and 25 test points is based on thickness reduction of the conveyor structure using Ultrasonic Thickness Gauge TT 130. This measurement obtain information about the actual thickness of the conveyor structure which then becomes the input for calculating the Corrosion Rate and Remaining Life of the conveyor structure.The research conditions from 2015-2019 showed rainfall of 206.78 mm/year, air temperature of 28.09OC, and humidity of 78.78%. These environmental conditions will cause corrosion when interacting with the conveyor structure. Corrosion that occurs on the conveyor structure is a type of uniform corrosion. Corrosion control is carried out on the conveyor structure by using the three layers system coating method. This system consists of primary coating using Seaguard 5000, intermediate coating using Sherglass FF, and top coating using Aliphatic acrylic modified polyurethane.
Abstrak. Pengangkutan batubara di PT XYZ di Kabupaten Tanah Laut, Provinsi Kalimantan Selatan menggunakan alat angkut berupa conveyor. Struktur conveyor yang digunakan berbahan dasar baja karbon (low carbon steel) yang rentan terjadi korosi. Korosi yang terjadi pada struktur conveyor disebabkan karena adanya kerusakan pada coating akibat kontak dengan lingkungan. Oleh karena itu dilakukanlah penelitian pada struktur conveyor dengan tujuan untuk mengetahui jenis korosi dan metode pengendalian korosi yang diaplikasikan pada struktur conveyor. Metodologi pengukuran yang digunakan pada struktur conveyor sepanjang 90 meter dan 25 test point ini berdasarkan pengurangan ketebalan struktur conveyor menggunakan Ultrasonic Thickness Gauge TT 130. Pengukuran ini membantu dalam mengetahui tebal aktual struktur conveyor yang selanjutnya menjadi input untuk perhitungan Corrosion Rate dan Remaining Service Life struktur conveyor. Kondisi penelitian dari tahun 2015-2019 menunjukkan curah hujan sebesar 206,78 mm/tahun, temperatur udara sebesar 28,09OC, dan kelembapan udara sebesar 78,78%. Kondisi lingkungan ini akan menyebabkan korosi ketika berinteraksi dengan struktur conveyor. Korosi yang terjadi pada struktur conveyor merupakan jenis korosi merata. Metode pengendalian korosi yang diaplikasikan pada struktur conveyor adalah metode coating three layers system. Sistem ini terdiri dari primer coating menggunakan Seaguard 5000, intermediate coating menggunakan Sherglass FF, dan top coating menggunakan Aliphatic acrylic modified polyurethane.
摘要。南加里曼丹省Tanah Laut Regency的XYZ煤矿运输使用输送机等运输设备。输送机结构采用低碳钢,易受腐蚀。在输送机结构中发生的腐蚀是由于与环境接触导致涂层损坏造成的。因此,本文对输送机结构进行了研究,目的是了解腐蚀的类型以及适用于输送机结构的腐蚀控制方法。长度为90米,25个测试点的输送机结构的测量方法是基于使用超声波测厚仪TT 130对输送机结构进行减厚。该测量获得有关输送结构实际厚度的信息,然后成为计算输送结构腐蚀速率和剩余寿命的输入。2015-2019年研究条件为降雨量206.78 mm/年,气温28.09OC,湿度78.78%。这些环境条件在与输送机结构相互作用时会造成腐蚀。发生在输送机结构上的腐蚀是一种均匀腐蚀。采用三层体系涂覆法对输送机结构进行腐蚀控制。该系统由Seaguard 5000为主涂层,Sherglass FF为中间涂层,脂族丙烯酸改性聚氨酯为面涂层组成。Abstrak。Pengangkutan batubara di PT XYZ di Kabupaten Tanah Laut, province Kalimantan Selatan menggunakan alat angkut berupa输送带。Struktur输送机yang digunakan berbahan dasar baja carbon(低碳钢)yang rentan terjadi korosi。Korosi yang terjadi pada结构输送机disebabkan karena adanya kerusakan pada涂层akibat kontakan lingkungan。Oleh karena itu dilakukkanlah penelitian板式输送机邓安tujuan untuk mengetahui jenis korosi danmede pengendalian korosi yang diaplikasikan板式输送机。方法penguin kuran yang digunakan padadstructuran输送机sepanjang 90米丹25测试点ini berdasarkan pengurangan ketebalan structuran输送机menggunakan超声波厚度计tt130。结构式输送机结构式输送机结构式输送机结构式输送机结构式输送机Kondisi penelitian dari tahun 2015-2019 menunjukkan curah hujan sebesar 206,78 mm/tahun,温度udara sebesar 28,09 oc, dan kelembapan udara sebesar 78,78。Kondisi lingkungan ini akan menyebabkan korosi ketika berinteraksi dengan结构输送机。Korosi yang terjadi pada结构输送机merupakan jenis Korosi merata。Metode pengendalian korosi yang diaplikasikan padada结构输送机adalah Metode涂层三层系统。系统中底漆为蒙古那坎Seaguard 5000,中间漆为蒙古那坎Sherglass FF,单面漆为蒙古那坎脂肪族丙烯酸改性聚氨酯。