Primary control with batteries

E. Waffenschmidt
{"title":"Primary control with batteries","authors":"E. Waffenschmidt","doi":"10.1109/IESC.2016.7569492","DOIUrl":null,"url":null,"abstract":"In the near future renewable energy decentralized generators must provide grid control. Storages are attractive for grid control and especially for primary reserve power. However, providing primary control power with batteries is limited by the capacity of the battery. Losses and imprecise frequency measurements may soon lead to a depleted or full storage. It is possible to reduce this issue by making use of several parameters of freedom. Especially attractive is the compensation of a systematic frequency measurement error by applying a running average correction signal.","PeriodicalId":158346,"journal":{"name":"2016 International Energy and Sustainability Conference (IESC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Energy and Sustainability Conference (IESC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IESC.2016.7569492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

In the near future renewable energy decentralized generators must provide grid control. Storages are attractive for grid control and especially for primary reserve power. However, providing primary control power with batteries is limited by the capacity of the battery. Losses and imprecise frequency measurements may soon lead to a depleted or full storage. It is possible to reduce this issue by making use of several parameters of freedom. Especially attractive is the compensation of a systematic frequency measurement error by applying a running average correction signal.
带蓄电池的初级控制
在不久的将来,可再生能源分散式发电机必须提供电网控制。储能系统对电网控制,特别是一次备用电源具有很大的吸引力。然而,用电池提供主要控制电源受到电池容量的限制。损耗和不精确的频率测量可能很快导致耗尽或满存储。利用几个自由度参数可以减少这个问题。特别吸引人的是通过应用运行平均校正信号来补偿系统频率测量误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信