The PHELIX pulsed power project: Bringing portable magnetic drive to proton radiography

C. Rousculp, W. Reass, D. Oró, P. Turchi, B. Hollander, J. Griego, R. Reinovsky
{"title":"The PHELIX pulsed power project: Bringing portable magnetic drive to proton radiography","authors":"C. Rousculp, W. Reass, D. Oró, P. Turchi, B. Hollander, J. Griego, R. Reinovsky","doi":"10.1109/MEGAGAUSS.2012.6781454","DOIUrl":null,"url":null,"abstract":"The PHELIX pulsed power project will introduce magnetically driven hydrodynamics experiments to the Los Alamos National Laboratory's proton radiography facility (pRad). The Precision High Energy-density Liner Implosion eXperiment (PHELIX) has been commissioned at Los Alamos. A small footprint capacitor bank consisting of four parallel, air-insulated, single-stage, marx units (U ~ 300 kJ) is cable coupled to a toroidal, current step-up transformer to deliver multi-megampere current pulses (tpulse ~10 μs) to cm size cylindrical loads. In a sequence of tests the performance of each component (capacitor bank and transformer) was evaluated and compared to a computer model. The transformer coupling was observed to be k ~ 0.93. A series of liner implosion experiments has been performed in which an aluminum liner (R ~3 cm, r = 0.8 mm, L = 3 cm) was accelerated to a velocity of ~ 1 km/s. The suite of machine diagnostics included linear Rogowski coils and Faraday rotation for current measurements. The experimental diagnostics include B-dot probes, multi-channel photon Doppler velocimetry (PDV), and single-frame, flash X-radiography to evaluate the performance of the high precision liner implosion. Currently, work is focused on integrating PHELIX into normal operations with the 800 MeV proton radiography facility at the Los Alamos Neutron Science Center (LANSCE), to enable high-resolution, high-frame-rate imaging of hydrodynamic experiments.","PeriodicalId":299352,"journal":{"name":"2012 14th International Conference on Megagauss Magnetic Field Generation and Related Topics (MEGAGAUSS)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 14th International Conference on Megagauss Magnetic Field Generation and Related Topics (MEGAGAUSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEGAGAUSS.2012.6781454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The PHELIX pulsed power project will introduce magnetically driven hydrodynamics experiments to the Los Alamos National Laboratory's proton radiography facility (pRad). The Precision High Energy-density Liner Implosion eXperiment (PHELIX) has been commissioned at Los Alamos. A small footprint capacitor bank consisting of four parallel, air-insulated, single-stage, marx units (U ~ 300 kJ) is cable coupled to a toroidal, current step-up transformer to deliver multi-megampere current pulses (tpulse ~10 μs) to cm size cylindrical loads. In a sequence of tests the performance of each component (capacitor bank and transformer) was evaluated and compared to a computer model. The transformer coupling was observed to be k ~ 0.93. A series of liner implosion experiments has been performed in which an aluminum liner (R ~3 cm, r = 0.8 mm, L = 3 cm) was accelerated to a velocity of ~ 1 km/s. The suite of machine diagnostics included linear Rogowski coils and Faraday rotation for current measurements. The experimental diagnostics include B-dot probes, multi-channel photon Doppler velocimetry (PDV), and single-frame, flash X-radiography to evaluate the performance of the high precision liner implosion. Currently, work is focused on integrating PHELIX into normal operations with the 800 MeV proton radiography facility at the Los Alamos Neutron Science Center (LANSCE), to enable high-resolution, high-frame-rate imaging of hydrodynamic experiments.
PHELIX脉冲功率项目:将便携式磁性驱动器引入质子放射照相
philix脉冲功率项目将为洛斯阿拉莫斯国家实验室的质子射线照相设备(pRad)引入磁驱动流体动力学实验。高精度高能量密度衬里内爆实验(philix)已在美国洛斯阿拉莫斯国家实验室投入使用。由四个并联、空气绝缘、单级、马克思单元(U ~ 300 kJ)组成的小封装电容器组与环形电流升压变压器电缆耦合,可向厘米大小的圆柱形负载提供数兆培电流脉冲(tpulse ~10 μs)。在一系列测试中,对每个组件(电容器组和变压器)的性能进行了评估,并与计算机模型进行了比较。变压器耦合的k ~ 0.93。用铝衬垫(R ~3 cm, R = 0.8 mm, L = 3 cm)加速至1 km/s,进行了一系列衬垫内爆实验。机器诊断套件包括用于电流测量的线性Rogowski线圈和法拉第旋转。实验诊断包括b点探针、多通道光子多普勒测速(PDV)和单帧闪光x射线摄影,以评估高精度线性内爆的性能。目前,工作重点是将PHELIX与洛斯阿拉莫斯中子科学中心(LANSCE)的800 MeV质子射线照相设备整合到正常操作中,以实现高分辨率,高帧率的流体动力学实验成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信