Energy Efficient Free Cooling System for Data Centers

Christy Sujatha D., Satheesh Abimannan
{"title":"Energy Efficient Free Cooling System for Data Centers","authors":"Christy Sujatha D., Satheesh Abimannan","doi":"10.1109/CloudCom.2011.100","DOIUrl":null,"url":null,"abstract":"A data center is a facility used to keep computer related equipments. It is estimated that heat production rate of the data center is doubled in every two years and hence the inevitability of the cooling system gets increased. In due course power consumption of a data center is augmented and more cost is spent on the power usage of the cooling system rather than the equipment purchase. As a result power savings for the cooling system is strongly desired. In this paper we conferred two primary free cooling systems namely air economizer and water economizer. A free cooling economizer system uses the outside air which is forced to the data center when outside climate is suitable to meet the ASHRE's cooling requirements. We have also conducted a survey and simulation based estimation using TRACE[TM] Chiller Plant Analyzer Tool. In this study, the energy consumption in a data center using conventional cooling system is compared with Air Economizer and Water Economizer for three different Zones namely Chicago, Atlanta and Phoenix in view of the fact that the outside air is relatively cool most of the year. From the projected result it is observed that both economizers reduce energy and cost when compared with conventional system and the usage of Economizer permits the chiller to shut down or reduce chiller energy load under suitable weather conditions. The results show that Water economizers are shown to consistently outperform air economizer which provides significant improvement in cooling system efficiency and cost at data center. The performance ratio of the conventional, air economizer and the water economizers are 50%, 76% and 79% respectively that shows economizers provide more savings relative to the conventional system.","PeriodicalId":427190,"journal":{"name":"2011 IEEE Third International Conference on Cloud Computing Technology and Science","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Third International Conference on Cloud Computing Technology and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CloudCom.2011.100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

Abstract

A data center is a facility used to keep computer related equipments. It is estimated that heat production rate of the data center is doubled in every two years and hence the inevitability of the cooling system gets increased. In due course power consumption of a data center is augmented and more cost is spent on the power usage of the cooling system rather than the equipment purchase. As a result power savings for the cooling system is strongly desired. In this paper we conferred two primary free cooling systems namely air economizer and water economizer. A free cooling economizer system uses the outside air which is forced to the data center when outside climate is suitable to meet the ASHRE's cooling requirements. We have also conducted a survey and simulation based estimation using TRACE[TM] Chiller Plant Analyzer Tool. In this study, the energy consumption in a data center using conventional cooling system is compared with Air Economizer and Water Economizer for three different Zones namely Chicago, Atlanta and Phoenix in view of the fact that the outside air is relatively cool most of the year. From the projected result it is observed that both economizers reduce energy and cost when compared with conventional system and the usage of Economizer permits the chiller to shut down or reduce chiller energy load under suitable weather conditions. The results show that Water economizers are shown to consistently outperform air economizer which provides significant improvement in cooling system efficiency and cost at data center. The performance ratio of the conventional, air economizer and the water economizers are 50%, 76% and 79% respectively that shows economizers provide more savings relative to the conventional system.
数据中心节能自然冷却系统
数据中心是用来保存计算机相关设备的设施。据估计,数据中心的产热速度每两年翻一番,因此冷却系统的必要性增加了。在适当的时候,数据中心的电力消耗会增加,更多的成本花在冷却系统的电力使用上,而不是购买设备。因此,冷却系统的节能是非常需要的。本文提出了两种主要的自然冷却系统,即空气省煤器和水省煤器。自由冷却省煤器系统使用外部空气,当外部气候适合ASHRE的冷却要求时,将外部空气强制送入数据中心。我们还使用TRACE[TM]冷冻厂分析工具进行了基于调查和模拟的估算。在本研究中,针对芝加哥、亚特兰大和凤凰城三个不同区域的室外空气在一年中大部分时间相对凉爽的事实,比较了使用传统冷却系统的数据中心与空气省煤器和水省煤器的能耗。从预测结果可以看出,与传统系统相比,省煤器可以减少能源和成本,并且在适当的天气条件下,使用省煤器可以使冷水机组关闭或减少冷水机组的能量负荷。结果表明,水省煤器的表现始终优于空气省煤器,这在数据中心的冷却系统效率和成本方面提供了显著的改善。常规省煤器、空气省煤器和水省煤器的性能比分别为50%、76%和79%,说明与常规系统相比,省煤器提供了更多的节约。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信