Evaluation of a power quality monitoring system

W. Hipp, H. Renner
{"title":"Evaluation of a power quality monitoring system","authors":"W. Hipp, H. Renner","doi":"10.1109/PQ.2008.4653736","DOIUrl":null,"url":null,"abstract":"Since the liberalization of the electrical power market in most EU countries regulation authorities have been founded to observe and regulate the quality of the delivered power. In order to meet the requirements resulting from this situation, grid providers have to be able to prove that European Standards for power quality (EN 50160) are obeyed in each consumer connection point and product liability laws are fulfilled. The purpose of this paper is to show how diverse disturbing sources spread out over the whole MV- and HV-grid. Furthermore the measured data of an existing power quality monitoring system consisting of about 200 measuring points inside of about 40 MV-grids which are fed by 2 HV-grids will be analyzed in order to evaluate the best positions for power quality measuring stations.","PeriodicalId":429968,"journal":{"name":"2008 Power Quality and Supply Reliability Conference","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Power Quality and Supply Reliability Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2008.4653736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Since the liberalization of the electrical power market in most EU countries regulation authorities have been founded to observe and regulate the quality of the delivered power. In order to meet the requirements resulting from this situation, grid providers have to be able to prove that European Standards for power quality (EN 50160) are obeyed in each consumer connection point and product liability laws are fulfilled. The purpose of this paper is to show how diverse disturbing sources spread out over the whole MV- and HV-grid. Furthermore the measured data of an existing power quality monitoring system consisting of about 200 measuring points inside of about 40 MV-grids which are fed by 2 HV-grids will be analyzed in order to evaluate the best positions for power quality measuring stations.
电能质量监测系统的评估
自电力市场开放以来,大多数欧盟国家都建立了监管机构来观察和规范输送的电力质量。为了满足这种情况产生的要求,电网供应商必须能够证明在每个消费者连接点都遵守欧洲电力质量标准(EN 50160),并遵守产品责任法。本文的目的是展示不同的干扰源如何分布在整个中高压电网上。此外,将分析现有电能质量监测系统的测量数据,该系统由约40个mv电网内的约200个测量点组成,这些测量点由2个高压电网供电,以评估电能质量测量站的最佳位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信