{"title":"Reference standard design for flow calibration of mechanical ventilator and lung simulator calibrators","authors":"Hakan Kaykisizh, Vahit Çiftçi","doi":"10.1109/BIYOMUT.2010.5479874","DOIUrl":null,"url":null,"abstract":"Special design flow calibrators are used for calibration of mechanical ventilators and lung simulators. It is necessary that these calibrators are connected to traceability chain via national standards. Mathematical models explaining the respiratory mechanics should be analyzed carefully before designing such a reference system for the purpose of calibration of flow calibrators. The purpose is to obtain a reference flow rate that shows a sinusoidal character. This paper explains the modeling studies and parameter considerations for design of the national reference standard at TUBITAK UME.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 15th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2010.5479874","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Special design flow calibrators are used for calibration of mechanical ventilators and lung simulators. It is necessary that these calibrators are connected to traceability chain via national standards. Mathematical models explaining the respiratory mechanics should be analyzed carefully before designing such a reference system for the purpose of calibration of flow calibrators. The purpose is to obtain a reference flow rate that shows a sinusoidal character. This paper explains the modeling studies and parameter considerations for design of the national reference standard at TUBITAK UME.
机械呼吸机和肺模拟器校准器流量校准参考标准设计
特殊设计的流量校准器用于校准机械呼吸机和肺模拟器。这些校准器必须通过国家标准连接到可追溯链上。在设计用于校准流量校准器的参考系统之前,应仔细分析解释呼吸力学的数学模型。目的是获得一个显示正弦特性的参考流量。本文介绍了TUBITAK UME国家参考标准的建模研究和设计参数考虑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信