[Measurement of tetrachloroethylene emissions at dry-cleaning establishments and their relation to MPEL values].

B Ponsold, H Kath
{"title":"[Measurement of tetrachloroethylene emissions at dry-cleaning establishments and their relation to MPEL values].","authors":"B Ponsold,&nbsp;H Kath","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The existing tetrachloroethylene was measured with the gas chromatographic method (FID detector), the spectro-photometric method (ICI Manual) based on the Fujiwava reaction, and using the gas detector (as approximation). The results obtained, however, do not differ in principle. Contaminated room air and leakages are the main sources of tetrachloroethylene at the dry cleaners and prevent the lowering of the traditional MEC value set at 100 mgm-3. Therefore the trend of diminishing the emission of exhaust air form machines can be neglected as factor in a general assessment. From the point of process engineering the problem of absorption of tetrachloroethylene in the indoor air with in the concentration range of 50 to 500 mgm-3 will be in the foreground. The excess of the MEC values is reflected by excess of the MIC values. It is difficult to keep to the MIC value within a distance of less than 50 m from the affected area of a dry cleaner.</p>","PeriodicalId":76839,"journal":{"name":"Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete","volume":"36 10","pages":"525-7"},"PeriodicalIF":0.0000,"publicationDate":"1990-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The existing tetrachloroethylene was measured with the gas chromatographic method (FID detector), the spectro-photometric method (ICI Manual) based on the Fujiwava reaction, and using the gas detector (as approximation). The results obtained, however, do not differ in principle. Contaminated room air and leakages are the main sources of tetrachloroethylene at the dry cleaners and prevent the lowering of the traditional MEC value set at 100 mgm-3. Therefore the trend of diminishing the emission of exhaust air form machines can be neglected as factor in a general assessment. From the point of process engineering the problem of absorption of tetrachloroethylene in the indoor air with in the concentration range of 50 to 500 mgm-3 will be in the foreground. The excess of the MEC values is reflected by excess of the MIC values. It is difficult to keep to the MIC value within a distance of less than 50 m from the affected area of a dry cleaner.

[干洗店四氯乙烯排放量的测量及其与MPEL值的关系]。
现有四氯乙烯的测定方法分别为气相色谱法(FID检测器)、基于藤波反应的光谱光度法(ICI手册)和近似气体检测器。然而,所得到的结果在原则上没有差别。被污染的室内空气和泄漏是干洗店四氯乙烯的主要来源,并阻止了传统MEC值设定为100 mg -3的降低。因此,在一般评估中,减少机器废气排放的趋势可以忽略不计。从工艺工程的角度来看,室内空气中浓度在50 ~ 500 mg -3的四氯乙烯的吸收问题将成为研究的重点。MEC值的过剩反映在MIC值的过剩上。在距离干洗店受影响区域小于50米的范围内,很难保持MIC值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信