{"title":"Activities of the task group 8 on thin film PV module reliability (Conference Presentation)","authors":"N. Dhere","doi":"10.1117/12.2237449","DOIUrl":null,"url":null,"abstract":"Photovoltaic (PV) modules and systems are being used increasingly to provide renewable energy to schools, residences, small businesses and utilities. At this time, the home owners and small businesses have considerable difficulty in detecting module and/or system degradation and especially enforcing warranty. It needs to be noted that IEC 61215-1 (test req.), -2 (test proc.) and -1-1 (c-Si) are forecasted to be circulated end of Feb 2016 and only editorial changes would be possible. 61215 series does include thin film technologies and would be replacing 61646. Moreover, IEC 61215-1, section 7.2 power output and electric circuitry does contain significant changes to acceptance criteria regarding rated label values, particularly rated power. Even though it is believed that consensus could be achieved within IEC TC82 WG2, some of the smaller players that do not participate actively in IEC TC82 – may not be surprised and must be informed. The other tech specific parts 61215-1-2 (CdTe), -1-3 (a-Si, µc-Si) and -1-4 (CIS, CIGS) are out for comments. The IEC closing date was January 29, 2016. The additions alternative damp heat (DH) test proposed Solar Frontier is being reviewed. In the past, only 600 V systems were permitted in the grid-connected residential and commercial systems in the US. The US commercial systems can now use higher voltage (1,000-1500V) in order to reduce BOS component costs. It is believed that there would not be any problems. The Task Group 8 is collecting data on higher voltage systems.","PeriodicalId":140444,"journal":{"name":"Optics + Photonics for Sustainable Energy","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optics + Photonics for Sustainable Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2237449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Photovoltaic (PV) modules and systems are being used increasingly to provide renewable energy to schools, residences, small businesses and utilities. At this time, the home owners and small businesses have considerable difficulty in detecting module and/or system degradation and especially enforcing warranty. It needs to be noted that IEC 61215-1 (test req.), -2 (test proc.) and -1-1 (c-Si) are forecasted to be circulated end of Feb 2016 and only editorial changes would be possible. 61215 series does include thin film technologies and would be replacing 61646. Moreover, IEC 61215-1, section 7.2 power output and electric circuitry does contain significant changes to acceptance criteria regarding rated label values, particularly rated power. Even though it is believed that consensus could be achieved within IEC TC82 WG2, some of the smaller players that do not participate actively in IEC TC82 – may not be surprised and must be informed. The other tech specific parts 61215-1-2 (CdTe), -1-3 (a-Si, µc-Si) and -1-4 (CIS, CIGS) are out for comments. The IEC closing date was January 29, 2016. The additions alternative damp heat (DH) test proposed Solar Frontier is being reviewed. In the past, only 600 V systems were permitted in the grid-connected residential and commercial systems in the US. The US commercial systems can now use higher voltage (1,000-1500V) in order to reduce BOS component costs. It is believed that there would not be any problems. The Task Group 8 is collecting data on higher voltage systems.
第八任务组关于薄膜光伏组件可靠性的活动(会议报告)
光伏(PV)模块和系统越来越多地用于为学校、住宅、小型企业和公用事业提供可再生能源。此时,业主和小型企业在检测模块和/或系统退化,特别是执行保修方面有相当大的困难。需要注意的是,IEC 61215-1(测试要求)、-2(测试过程)和-1-1 (c-Si)预计将于2016年2月底发布,只有编辑修改是可能的。61215系列确实包括薄膜技术,将取代61646。此外,IEC 61215-1第7.2节功率输出和电路确实对额定标签值的接受标准进行了重大更改,特别是额定功率。尽管相信在IEC TC82 WG2内可以达成共识,但一些不积极参与IEC TC82的小型参与者可能不会感到惊讶,必须告知他们。其他技术特定部件61215-1-2 (CdTe), -1-3 (a-Si,µc-Si)和-1-4 (CIS, CIGS)已公开征求意见。IEC截止日期为2016年1月29日。太阳能前沿(Solar Frontier)新增的可选湿热(DH)测试方案正在进行审核。过去,在美国,只有600 V的系统被允许用于并网的住宅和商业系统。美国商业系统现在可以使用更高的电压(1000 - 1500v),以降低BOS组件成本。相信不会有任何问题。第八任务组正在收集高压系统的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信