[Continuous intracorporeal glucose measurement using enzyme electrodes].

E Brunstein, P Abel, K Rebrin, U Fischer
{"title":"[Continuous intracorporeal glucose measurement using enzyme electrodes].","authors":"E Brunstein,&nbsp;P Abel,&nbsp;K Rebrin,&nbsp;U Fischer","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An enzyme electrode (GOD, Pt-Ag/AgCl) is introduced for amperometric measurement of the intracorporal glucose concentration in the subcutaneous tissue. Changes of the glucose concentration in the peripheral blood (PG) were induced by glucose- respectively insulin-infusion in healthy dogs. PG was compared with values found by out means of a sensor implanted in the necks of the dogs (SG). The regression equation SG = 0.81 PG - 1.39 was calculated by analysing 62 steady state levels. The regression delta SG = 0.83 delta PG + 0.22 submitted for the deviation of the normoglycemic base-level. A sensibility loss of the sensor of about 10% appears after an implantation duration of 7.5 hours in medium. Conclusions for the further development of the sensors follows especially with the in vivo functions (biocompatibility, diminution, sterilisation).</p>","PeriodicalId":77647,"journal":{"name":"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR","volume":"23 2","pages":"95-8"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An enzyme electrode (GOD, Pt-Ag/AgCl) is introduced for amperometric measurement of the intracorporal glucose concentration in the subcutaneous tissue. Changes of the glucose concentration in the peripheral blood (PG) were induced by glucose- respectively insulin-infusion in healthy dogs. PG was compared with values found by out means of a sensor implanted in the necks of the dogs (SG). The regression equation SG = 0.81 PG - 1.39 was calculated by analysing 62 steady state levels. The regression delta SG = 0.83 delta PG + 0.22 submitted for the deviation of the normoglycemic base-level. A sensibility loss of the sensor of about 10% appears after an implantation duration of 7.5 hours in medium. Conclusions for the further development of the sensors follows especially with the in vivo functions (biocompatibility, diminution, sterilisation).

[酶电极连续测定体内葡萄糖]。
介绍了一种酶电极(GOD, Pt-Ag/AgCl)用于皮下组织体内葡萄糖浓度的安培测量。研究了糖-胰岛素分别输注对健康犬外周血葡萄糖浓度的影响。将PG与通过植入狗脖子的传感器(SG)获得的值进行比较。通过分析62个稳态水平,计算出回归方程SG = 0.81 PG - 1.39。对于正常血糖基础水平的偏差,提出回归delta SG = 0.83 delta PG + 0.22。在培养基中植入7.5小时后,传感器的灵敏度损失约10%。以下是传感器进一步发展的结论,特别是在体内功能(生物相容性,缩小,灭菌)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信