Accuracy evaluation on linear measurement through opto-electronic plethysmograph

F. Bastianini, E. Schena, S. Silvestri
{"title":"Accuracy evaluation on linear measurement through opto-electronic plethysmograph","authors":"F. Bastianini, E. Schena, S. Silvestri","doi":"10.1109/EMBC.2012.6674230","DOIUrl":null,"url":null,"abstract":"Opto-electronic plethysmograph (OEP) is a motion analysis device able to measure chest wal l motion and volume variation by surface measurement. The estimation is obtained through displacements measurements of markers placed on the thorax. Therefore OEP accuracy on markers' displacement measurements may play a role in the volume's measurement. The aim of present work is to evaluate OEP accuracy in the estimation of linear displacements, taking into account the contribution due of number of cameras, markers size and displacement magni tude. A linear DC-motor was used to move the marker fixed on its shaft. Trials have been carried out varying 1) marker size (diameters of 6 mm and 12 mm) , 2) cameras number (2, 4, and 6) and 3) the magni tude of displacements ( from 10 μm up to 200 μm). Number of cameras and marker size do not seem to play a crucial role as far as it concerns accuracy on linear displacements. The relative percentage uncertainty decreases from 10% to 6% for marker A, increasing number of cameras from 2 to 6; for marker B, the percentage relative error decreases from 17% to 10%, increasing number of cameras from 2 to 4. Moreover, OEP shows a discrimination threshold of 30 μm.","PeriodicalId":218020,"journal":{"name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC.2012.6674230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Opto-electronic plethysmograph (OEP) is a motion analysis device able to measure chest wal l motion and volume variation by surface measurement. The estimation is obtained through displacements measurements of markers placed on the thorax. Therefore OEP accuracy on markers' displacement measurements may play a role in the volume's measurement. The aim of present work is to evaluate OEP accuracy in the estimation of linear displacements, taking into account the contribution due of number of cameras, markers size and displacement magni tude. A linear DC-motor was used to move the marker fixed on its shaft. Trials have been carried out varying 1) marker size (diameters of 6 mm and 12 mm) , 2) cameras number (2, 4, and 6) and 3) the magni tude of displacements ( from 10 μm up to 200 μm). Number of cameras and marker size do not seem to play a crucial role as far as it concerns accuracy on linear displacements. The relative percentage uncertainty decreases from 10% to 6% for marker A, increasing number of cameras from 2 to 6; for marker B, the percentage relative error decreases from 17% to 10%, increasing number of cameras from 2 to 4. Moreover, OEP shows a discrimination threshold of 30 μm.
光电容积描记器线性测量的精度评价
光电容积描记仪(OEP)是一种运动分析设备,能够通过表面测量来测量胸壁运动和容积变化。该估计是通过放置在胸腔上的标记物的位移测量获得的。因此,标记物位移测量的OEP精度可能在体积测量中起作用。本工作的目的是评估OEP在估计线性位移时的准确性,同时考虑到相机数量、标记大小和位移幅度的贡献。直线直流电机用于移动固定在其轴上的标记。试验包括:1)标记尺寸(直径为6毫米和12毫米),2)相机数量(2、4和6)和3)位移幅度(从10 μm到200 μm)。相机的数量和标记的大小似乎并没有发挥关键作用,因为它涉及到线性位移的精度。标记A的相对百分比不确定度从10%降低到6%,相机数量从2个增加到6个;对于标记B,相对误差百分比从17%减少到10%,相机数量从2个增加到4个。OEP的识别阈值为30 μm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信