The site characterization of central jakarta soft soil using CPTu and laboratory test

A. Permana, P. Rahardjo
{"title":"The site characterization of central jakarta soft soil using CPTu and laboratory test","authors":"A. Permana, P. Rahardjo","doi":"10.56144/igj.v1i1.6","DOIUrl":null,"url":null,"abstract":"Construction activities has been named as one of the contributing factors to Jakarta’s alarming rate of land subsidence, which ranges between 1 to 15 cm annually, and up to 28 cm in some locations. This problem is commonly known as settlement, and the affected soft soil is usually attributed to under-consolidating soil (UC). In regards to that matter, this study aims to characterize the soft soil layer in Central Jakarta using the Cone Penetration Test with pore pressure measurement (CPTu) and laboratory assessment. In addition, Undrained Shear Strength () and Pore Pressure Ratio (and ) methods were used to estimate the over-consolidation Ratio (OCR) values. The data collected from 94 boreholes and 30 CPTu showed the soft soil layers in Central Jakarta, which was dominated by high-plasticity silty clay (CH) and clayey silt (MH). The layers are detected between the depth of 0 – 25 m and are characterized by high natural moisture content, void ratio, liquidity index, and compression index values. Within this layer of under consolidated soils, the indication of relatively low dry unit weight was also present. Furthermore, the laboratory tests showed several correlations related to under-consolidating soil, i.e. void ratio to in-situ effective stress, void ratio to compression index, and compression index to natural moisture content. The CPTu test interpretations returned a number of under-consolidation soil layer samples in Central Jakarta. Moreover, the result also indicates the presence of under-consolidating properties, as well as normally consolidated and lightly over-consolidated.","PeriodicalId":439927,"journal":{"name":"Indonesian Geotechnical Journal","volume":"181 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Geotechnical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56144/igj.v1i1.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Construction activities has been named as one of the contributing factors to Jakarta’s alarming rate of land subsidence, which ranges between 1 to 15 cm annually, and up to 28 cm in some locations. This problem is commonly known as settlement, and the affected soft soil is usually attributed to under-consolidating soil (UC). In regards to that matter, this study aims to characterize the soft soil layer in Central Jakarta using the Cone Penetration Test with pore pressure measurement (CPTu) and laboratory assessment. In addition, Undrained Shear Strength () and Pore Pressure Ratio (and ) methods were used to estimate the over-consolidation Ratio (OCR) values. The data collected from 94 boreholes and 30 CPTu showed the soft soil layers in Central Jakarta, which was dominated by high-plasticity silty clay (CH) and clayey silt (MH). The layers are detected between the depth of 0 – 25 m and are characterized by high natural moisture content, void ratio, liquidity index, and compression index values. Within this layer of under consolidated soils, the indication of relatively low dry unit weight was also present. Furthermore, the laboratory tests showed several correlations related to under-consolidating soil, i.e. void ratio to in-situ effective stress, void ratio to compression index, and compression index to natural moisture content. The CPTu test interpretations returned a number of under-consolidation soil layer samples in Central Jakarta. Moreover, the result also indicates the presence of under-consolidating properties, as well as normally consolidated and lightly over-consolidated.
利用CPTu和室内试验对雅加达中部软土进行了场地表征
建筑活动被认为是造成雅加达地面下沉速度惊人的因素之一,每年下沉1到15厘米,在一些地方高达28厘米。这个问题通常被称为沉降,而受影响的软土通常归因于欠固结土(UC)。关于这一问题,本研究旨在利用孔隙压力测量(CPTu)和实验室评估的锥贯入试验来表征雅加达中部软土层。此外,采用不排水抗剪强度()和孔隙压力比()方法估算超固结比(OCR)值。94个钻孔和30个CPTu的数据表明,雅加达中部的软土层以高塑性粉质粘土(CH)和粘质粉砂(MH)为主。地层深度在0 ~ 25 m之间,具有较高的天然含水率、孔隙比、流动性指数和压缩指数等特征。在这一层下固结土中,也存在相对较低的干单位重的迹象。此外,室内试验还显示了与欠固结土有关的几个相关性,即孔隙比与原位有效应力、孔隙比与压缩指数、压缩指数与自然含水量。CPTu测试解释返回了雅加达中部一些未固结土层样品。此外,结果还表明存在欠固结性质,以及正常固结和轻度过固结。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信