Design of Low Power Pulse Oximeter for Early Detection of Hypoxemia

Komal Kashish, M. Priya, Piyush Yadav
{"title":"Design of Low Power Pulse Oximeter for Early Detection of Hypoxemia","authors":"Komal Kashish, M. Priya, Piyush Yadav","doi":"10.1109/ICMETE.2016.29","DOIUrl":null,"url":null,"abstract":"This paper involves designing a low power yet effective pulse oximetry system for detection of Hypoxemia especially for patients from developing and under-developed nations where the cost of any medical device is a primary concern. For this non-invasive technique to draw results from the behavior of light absorption pattern shown by blood, we decided on using a simple red LED and an infrared LED, with wavelength of 660nm and 940nm respectively. We used a receiver module on the other side to collect the refracted light. As predicted, the graph of the refracted light intensity mimicked the heart rate pattern of an individual. This proved to be helpful in drawing results such as heart rate and oxygen saturation level in the blood.","PeriodicalId":167368,"journal":{"name":"2016 International Conference on Micro-Electronics and Telecommunication Engineering (ICMETE)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Micro-Electronics and Telecommunication Engineering (ICMETE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMETE.2016.29","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

This paper involves designing a low power yet effective pulse oximetry system for detection of Hypoxemia especially for patients from developing and under-developed nations where the cost of any medical device is a primary concern. For this non-invasive technique to draw results from the behavior of light absorption pattern shown by blood, we decided on using a simple red LED and an infrared LED, with wavelength of 660nm and 940nm respectively. We used a receiver module on the other side to collect the refracted light. As predicted, the graph of the refracted light intensity mimicked the heart rate pattern of an individual. This proved to be helpful in drawing results such as heart rate and oxygen saturation level in the blood.
低氧血症早期检测低功率脉搏血氧仪的设计
本文涉及设计一种低功耗但有效的脉搏血氧仪系统,用于检测低氧血症,特别是对于发展中国家和欠发达国家的患者,任何医疗设备的成本都是主要关注的问题。对于这种非侵入性技术,从血液显示的光吸收模式行为中提取结果,我们决定使用简单的红色LED和红外LED,波长分别为660nm和940nm。我们在另一侧使用了一个接收模块来收集折射光。正如预测的那样,折射光强度的图表模拟了个体的心率模式。事实证明,这有助于绘制心率和血氧饱和度等结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信