Design of a Passive 10-DOF Arterial Puncturing Mechanism for Reducing Radiological Exposure

Muhammad Umair Ahmad Khan, Chang-Hwan Yoon, B. Yi
{"title":"Design of a Passive 10-DOF Arterial Puncturing Mechanism for Reducing Radiological Exposure","authors":"Muhammad Umair Ahmad Khan, Chang-Hwan Yoon, B. Yi","doi":"10.1109/URAI.2018.8441833","DOIUrl":null,"url":null,"abstract":"This paper proposes a new arterial puncturing mechanism that would reduce the radiation exposure for the surgeon. In vascular intervention procedures, a surgeon is usually exposed to a large amount of radiation that is harmful for the surgeon carrying out the surgery on a daily basis. A passive 10-DOF needle and guide wire insertion mechanism consists of 7 DOF articulated arm for positioning and 3 DOF for precise needle insertion. The guidewire can be inserted easily into a small, sterilizable tube attached to the mechanism. To test the feasibility of the device, animal experiment has been performed and radiation exposure has been measured with the help of dosimeter.","PeriodicalId":347727,"journal":{"name":"2018 15th International Conference on Ubiquitous Robots (UR)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 15th International Conference on Ubiquitous Robots (UR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/URAI.2018.8441833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper proposes a new arterial puncturing mechanism that would reduce the radiation exposure for the surgeon. In vascular intervention procedures, a surgeon is usually exposed to a large amount of radiation that is harmful for the surgeon carrying out the surgery on a daily basis. A passive 10-DOF needle and guide wire insertion mechanism consists of 7 DOF articulated arm for positioning and 3 DOF for precise needle insertion. The guidewire can be inserted easily into a small, sterilizable tube attached to the mechanism. To test the feasibility of the device, animal experiment has been performed and radiation exposure has been measured with the help of dosimeter.
一种减少辐射暴露的被动10自由度动脉穿刺机构的设计
本文提出了一种新的动脉穿刺机制,以减少外科医生的辐射暴露。在血管介入手术中,外科医生每天都会暴露在大量的辐射中,这对外科医生进行手术是有害的。无源10自由度针导丝插针机构由7自由度定位关节臂和3自由度精确插针组成。导丝可以很容易地插入一个小的,可消毒的管连接到机构。为了验证该装置的可行性,进行了动物实验,并借助剂量计测量了辐射暴露量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信