{"title":"Radiometric partial discharge location detection in medium voltage switchgears","authors":"M. Kannappan, C. Chakrabarty, G. C. Hock","doi":"10.1109/ICSIMA.2013.6717952","DOIUrl":null,"url":null,"abstract":"With the goal of providing stable electric quality and safety, it is important for power utilities to maintain their substation equipment by predicting and diagnosing their failures. The common failure is dielectric break downs due to insulator wear and tear. The goal is to develop a non destructive, non contact testing method to predict the location of these failures for preventive maintenance work. Partial discharges (PD) are emitted in the case of insulator deterioration. This paper focuses on the development of methods/algorithm to accurately locate and detect these PD signals within the 3D space of a medium voltage (MV) switch gear. Along with this, the methods described in this paper also allow for the PD to be detected while the switch gear is still live, omitting the need to disrupt power while detecting the PD location. The core principles chosen to detect PD in these conditions are radiometric signal detection. Results are presented showing the location ability both in simulation and live field conditions.","PeriodicalId":182424,"journal":{"name":"2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA)","volume":"562 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSIMA.2013.6717952","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

With the goal of providing stable electric quality and safety, it is important for power utilities to maintain their substation equipment by predicting and diagnosing their failures. The common failure is dielectric break downs due to insulator wear and tear. The goal is to develop a non destructive, non contact testing method to predict the location of these failures for preventive maintenance work. Partial discharges (PD) are emitted in the case of insulator deterioration. This paper focuses on the development of methods/algorithm to accurately locate and detect these PD signals within the 3D space of a medium voltage (MV) switch gear. Along with this, the methods described in this paper also allow for the PD to be detected while the switch gear is still live, omitting the need to disrupt power while detecting the PD location. The core principles chosen to detect PD in these conditions are radiometric signal detection. Results are presented showing the location ability both in simulation and live field conditions.
中压开关设备局部放电的辐射定位检测
为了保证稳定的电力质量和安全,对变电站设备进行故障预测和诊断是电力公司维护变电站设备的重要手段。常见的故障是由于绝缘子磨损引起的介电击穿。目标是开发一种非破坏性,非接触的测试方法,以预测这些故障的位置,以进行预防性维护工作。在绝缘子劣化的情况下会产生局部放电(PD)。本文的重点是在中压(MV)开关设备的三维空间内精确定位和检测这些PD信号的方法/算法的发展。除此之外,本文中描述的方法还允许在开关设备仍然带电的情况下检测PD,从而在检测PD位置时省去了中断电源的需要。在这种情况下,检测PD的核心原理是辐射信号检测。结果显示了该系统在模拟和现场条件下的定位能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信