{"title":"Spiral-scan Atomic Force Microscopy: A constant linear velocity approach","authors":"I. A. Mahmood, S. Moheimani","doi":"10.1109/NANO.2010.5698063","DOIUrl":null,"url":null,"abstract":"This paper describes an alternative method to the widely-used raster-scan technique for Atomic Force Microscopy (AFM). In this method, the sample is scanned in a spiral pattern instead of the well established raster trajectory. A spiral pattern is produced by applying cosine and sine signals with slowly varying amplitudes to the x-axis and y-axis of an AFM scanner respectively. In order to ensure that the spiral trajectory travels at a constant linear velocity (CLV), frequency and amplitude of the input signals are varied simultaneously in a way that the linear velocity of the scanner is kept constant. Experimental results obtained by implementing the CLV spiral scan on a commercial AFM indicate that, compared with the raster-scan method, high-quality AFM images of equal area and pitch can be generated two times faster and using half of the total traveled distance.","PeriodicalId":254587,"journal":{"name":"10th IEEE International Conference on Nanotechnology","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"10th IEEE International Conference on Nanotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NANO.2010.5698063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14
Abstract
This paper describes an alternative method to the widely-used raster-scan technique for Atomic Force Microscopy (AFM). In this method, the sample is scanned in a spiral pattern instead of the well established raster trajectory. A spiral pattern is produced by applying cosine and sine signals with slowly varying amplitudes to the x-axis and y-axis of an AFM scanner respectively. In order to ensure that the spiral trajectory travels at a constant linear velocity (CLV), frequency and amplitude of the input signals are varied simultaneously in a way that the linear velocity of the scanner is kept constant. Experimental results obtained by implementing the CLV spiral scan on a commercial AFM indicate that, compared with the raster-scan method, high-quality AFM images of equal area and pitch can be generated two times faster and using half of the total traveled distance.