[Fundamentals and requirements of peripheral electric nerve stimulation. A contribution to the improvement of safety standards in regional anesthesia].

IF 1.9 Q2 POLITICAL SCIENCE
Regional-Anaesthesie Pub Date : 1990-09-01
H Kaiser, H C Niesel, V Hans
{"title":"[Fundamentals and requirements of peripheral electric nerve stimulation. A contribution to the improvement of safety standards in regional anesthesia].","authors":"H Kaiser,&nbsp;H C Niesel,&nbsp;V Hans","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The use of a nerve stimulator allows an injection cannula to be located without the cooperation of the patient. Regional anesthesia thus becomes safer because the basic condition \"no paresthesia, no anesthesia\" becomes irrelevant. In accordance with the basic electrophysiological conditions, a stimulator should have the following properties: (1) adjustable constant current at resistances of 0.5-10 kOhm; (2) monophasic square-wave initial impulse; (3) impulse duration selectable (0.1 ms + 1 ms, and exactly adjustable; (4) impulse amplitude (0-5 mA) exactly adjusted, unequivocal scale graduation or current indicator, in particular in the range of 0.05-1.0 mA; (5) impulse frequency 1-2 (-3) Hz; (6) alarm at high impedance and check on electrical circuit; (7) battery test (indication of battery voltage); (8) unequivocal assignment of load end; (9) high-quality connecting cable and plug; and availability of (10) instructions for use with relevant parameters (tolerated variations, steady-state characteristic curves, etc.).</p>","PeriodicalId":77604,"journal":{"name":"Regional-Anaesthesie","volume":"13 7","pages":"143-7"},"PeriodicalIF":1.9000,"publicationDate":"1990-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Regional-Anaesthesie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"POLITICAL SCIENCE","Score":null,"Total":0}
引用次数: 0

Abstract

The use of a nerve stimulator allows an injection cannula to be located without the cooperation of the patient. Regional anesthesia thus becomes safer because the basic condition "no paresthesia, no anesthesia" becomes irrelevant. In accordance with the basic electrophysiological conditions, a stimulator should have the following properties: (1) adjustable constant current at resistances of 0.5-10 kOhm; (2) monophasic square-wave initial impulse; (3) impulse duration selectable (0.1 ms + 1 ms, and exactly adjustable; (4) impulse amplitude (0-5 mA) exactly adjusted, unequivocal scale graduation or current indicator, in particular in the range of 0.05-1.0 mA; (5) impulse frequency 1-2 (-3) Hz; (6) alarm at high impedance and check on electrical circuit; (7) battery test (indication of battery voltage); (8) unequivocal assignment of load end; (9) high-quality connecting cable and plug; and availability of (10) instructions for use with relevant parameters (tolerated variations, steady-state characteristic curves, etc.).

外周电神经刺激的基本原理和要求。对提高区域麻醉安全标准的贡献[j]。
使用神经刺激器可以在没有患者配合的情况下定位注射套管。区域麻醉因此变得更安全,因为“无感觉异常,无麻醉”的基本条件变得无关紧要。根据基本的电生理条件,刺激器应具有以下特性:(1)在0.5-10欧姆的电阻范围内可调恒流;(2)单相方波初始脉冲;(3)脉冲持续时间可选(0.1 ms + 1 ms,精确可调;(4)脉冲幅度(0-5毫安)精确调节,明确刻度刻度刻度或电流指示,特别是在0.05-1.0毫安范围内;(5)脉冲频率1 ~ 2 (-3)Hz;(6)高阻抗报警及电路检查;(7)电池试验(电池电压指示);(8)明确指定负载端;(9)高质量的连接电缆和插头;(10)相关参数(公差变化、稳态特性曲线等)的使用说明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信