{"title":"High frequency resonant MOS-FET DC-DC converter","authors":"K. Karube, T. Nomura, T. Nakano","doi":"10.1109/PESC.1988.18112","DOIUrl":null,"url":null,"abstract":"The authors explain the operation of a 100 W half-bridge resonant DC-DC converter, the method of determining the LC constants, and the condition of gate drive for achieving no-loss switching. Since the circuit operation is of a zero-volt-switching type, the switching loss at turn-off as well as turn-on can be zeroed by strengthening the gate drive circuit. It is confirmed that the LC constants can be determined by using a simple circuit model, and that setting a low resonant capacitor voltage is effective for reducing the main circuit loss. The characteristics of some DC-DC converters trial-manufactured on the basis of these results are shown.<<ETX>>","PeriodicalId":283605,"journal":{"name":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","volume":"239 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1988.18112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The authors explain the operation of a 100 W half-bridge resonant DC-DC converter, the method of determining the LC constants, and the condition of gate drive for achieving no-loss switching. Since the circuit operation is of a zero-volt-switching type, the switching loss at turn-off as well as turn-on can be zeroed by strengthening the gate drive circuit. It is confirmed that the LC constants can be determined by using a simple circuit model, and that setting a low resonant capacitor voltage is effective for reducing the main circuit loss. The characteristics of some DC-DC converters trial-manufactured on the basis of these results are shown.<>