Determination of the most suitable voltage control method depending on photovoltaic installation rate

Satoru Akagi, R. Takahashi, A. Kaneko, Masakazu Ito, J. Yoshinaga, Y. Hayashi, Hiromi Konda
{"title":"Determination of the most suitable voltage control method depending on photovoltaic installation rate","authors":"Satoru Akagi, R. Takahashi, A. Kaneko, Masakazu Ito, J. Yoshinaga, Y. Hayashi, Hiromi Konda","doi":"10.1109/APPEEC.2015.7380935","DOIUrl":null,"url":null,"abstract":"In this study, we determine the suitable method and timing for the renewal of the voltage control method using voltage control performance evaluated by the maximum photovoltaic (PV) installation rate possible without voltage deviation. The voltage control method is renewed when the voltage of a distribution system deviates with an existing voltage control method. We determine the most suitable voltage control method, which extends the most PV systems, and define its renewal timing as the moment when the PV installation causes voltage deviation. For the renewal of the voltage control method, changing the control operation of a load ratio control transformer (LRT) and the additional installation of a static VAR compensator (SVC) are considered. A numerical simulation is performed to calculate the limit of PV installation rate of each voltage control method to determine the suitable one and its renewal timing.","PeriodicalId":439089,"journal":{"name":"2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"111 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2015.7380935","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we determine the suitable method and timing for the renewal of the voltage control method using voltage control performance evaluated by the maximum photovoltaic (PV) installation rate possible without voltage deviation. The voltage control method is renewed when the voltage of a distribution system deviates with an existing voltage control method. We determine the most suitable voltage control method, which extends the most PV systems, and define its renewal timing as the moment when the PV installation causes voltage deviation. For the renewal of the voltage control method, changing the control operation of a load ratio control transformer (LRT) and the additional installation of a static VAR compensator (SVC) are considered. A numerical simulation is performed to calculate the limit of PV installation rate of each voltage control method to determine the suitable one and its renewal timing.
根据光伏装机率确定最合适的电压控制方法
在本研究中,我们通过最大光伏(PV)装机率评估电压控制性能来确定电压控制方法更新的合适方法和时机。当配电系统的电压与现有的电压控制方法发生偏差时,需要更新电压控制方法。我们确定了最合适的电压控制方法,扩展了最多的光伏系统,并将其更新时间定义为光伏安装产生电压偏差的时刻。对于电压控制方法的更新,考虑改变负载比控制变压器(LRT)的控制操作,并增加静态无功补偿器(SVC)。通过数值模拟计算了各种电压控制方法的光伏装机率极限,确定了适合的电压控制方法及其更新时机。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信