Implant stability related to insertion torque force and bone density: An in vitro study.

J. Tricio, D. van Steenberghe, D. Rosenberg, L. Duchateau
{"title":"Implant stability related to insertion torque force and bone density: An in vitro study.","authors":"J. Tricio, D. van Steenberghe, D. Rosenberg, L. Duchateau","doi":"10.1097/00008505-199600530-00031","DOIUrl":null,"url":null,"abstract":"Seventy-five implants were installed in 12 fresh ethanol-treated bovine ribs by use of a torque gauge manometer to measure the force needed to screw the implants fully into the bone. Digital radiographs were taken and a density histogram of the bone at the implant/bone interface was obtained. The damping characteristics of the implant/bone interface were assessed by tapping the abutment with the Periotest (PT) device. Abutments of several lengths screwed at 20 N/cm were used to conduct PT measurements and the PT values (PTVs) were related to the insertion torque force, the bone density, and implant and abutment length. The results indicated that high correlations exist between PTVs and insertion torque force (R value -0.74579), and PTVs and bone density (R value -0.83031). There was also a significant difference (p 0.001) among the PTVs of the different abutment lengths used. Implant length did not demonstrate influence on PTVs (p 0.3847).","PeriodicalId":185384,"journal":{"name":"The Journal of prosthetic dentistry","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of prosthetic dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00008505-199600530-00031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

Abstract

Seventy-five implants were installed in 12 fresh ethanol-treated bovine ribs by use of a torque gauge manometer to measure the force needed to screw the implants fully into the bone. Digital radiographs were taken and a density histogram of the bone at the implant/bone interface was obtained. The damping characteristics of the implant/bone interface were assessed by tapping the abutment with the Periotest (PT) device. Abutments of several lengths screwed at 20 N/cm were used to conduct PT measurements and the PT values (PTVs) were related to the insertion torque force, the bone density, and implant and abutment length. The results indicated that high correlations exist between PTVs and insertion torque force (R value -0.74579), and PTVs and bone density (R value -0.83031). There was also a significant difference (p 0.001) among the PTVs of the different abutment lengths used. Implant length did not demonstrate influence on PTVs (p 0.3847).
植入物稳定性与植入扭矩力和骨密度的关系:一项体外研究。
使用扭矩计压力计将75个植入物安装在12根新鲜乙醇处理的牛肋骨中,以测量将植入物完全螺钉入骨所需的力。拍摄数字x线片并获得种植体/骨界面处骨的密度直方图。通过使用Periotest (PT)装置轻叩基台来评估种植体/骨界面的阻尼特性。采用20n /cm螺钉固定不同长度的基台进行PT测量,PT值(PTVs)与插入扭矩、骨密度、种植体和基台长度有关。结果表明,PTVs与插入扭矩力(R值为-0.74579)、骨密度(R值为-0.83031)具有高度相关性。不同基台长度的ptv也有显著差异(p < 0.001)。种植体长度对ptv无影响(p 0.3847)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信