Normative macular cirrus spectral domain optical coherence tomography data in Indian pediatric population

Vishal Katiyar, Kumari Mugdha, Sonal Bangwal, S. Gupta
{"title":"Normative macular cirrus spectral domain optical coherence tomography data in Indian pediatric population","authors":"Vishal Katiyar, Kumari Mugdha, Sonal Bangwal, S. Gupta","doi":"10.4103/2347-5617.143818","DOIUrl":null,"url":null,"abstract":"Aim: Cirrus spectral-domain optical coherence tomography (SD-OCT) being noninvasive is gaining more popularity in identifying, monitoring, and classifying children with vitreo-retinal disorder. Normal values of cirrus SD-OCT from children are currently available from developed countries, but not from India. Objective: The primary objective of this study is to provide a normative pediatric database for macular thickness in healthy Indian children using the cirrus SD-OCT. Materials and Methods: The prospective observational study on 157 consecutive healthy children seen between January 2013 and January 2014. Included in the study were 157 subjects with no ocular abnormality, normal (20/20) visual acuity and normal fundoscopy. Cirrus HD-OCT (Carl Zeiss, Dublin, California, USA) device was used. Outcome: Study patients have a mean age of 12.59 ± 3.5 years, with 112 male (12.88 ± 3.5 years) and 45 female (11.8612.88 ± 3.5 years) children. In the linear regression analysis, changes in central subfield thickness and field of the outer macula were independently affected by increase in the age (β = −1.17-1.7, P = 0.004-0.022) and male are found to have significantly higher value when compared with the female (the t-test; t = 1.9-4.8, P = 0.00-0.24). Conclusion: This study established normal reference values for macular parameters measured by Cirrus SD-OCT in healthy Indian children 6-17 years of age, which is statistically different from the databases from other countries. It establishes the importance of the fact that age and gender warrants special consideration during cirrus SD-OCT interpretations in children.","PeriodicalId":201997,"journal":{"name":"Egyptian Retina Journal","volume":"904 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Retina Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/2347-5617.143818","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Aim: Cirrus spectral-domain optical coherence tomography (SD-OCT) being noninvasive is gaining more popularity in identifying, monitoring, and classifying children with vitreo-retinal disorder. Normal values of cirrus SD-OCT from children are currently available from developed countries, but not from India. Objective: The primary objective of this study is to provide a normative pediatric database for macular thickness in healthy Indian children using the cirrus SD-OCT. Materials and Methods: The prospective observational study on 157 consecutive healthy children seen between January 2013 and January 2014. Included in the study were 157 subjects with no ocular abnormality, normal (20/20) visual acuity and normal fundoscopy. Cirrus HD-OCT (Carl Zeiss, Dublin, California, USA) device was used. Outcome: Study patients have a mean age of 12.59 ± 3.5 years, with 112 male (12.88 ± 3.5 years) and 45 female (11.8612.88 ± 3.5 years) children. In the linear regression analysis, changes in central subfield thickness and field of the outer macula were independently affected by increase in the age (β = −1.17-1.7, P = 0.004-0.022) and male are found to have significantly higher value when compared with the female (the t-test; t = 1.9-4.8, P = 0.00-0.24). Conclusion: This study established normal reference values for macular parameters measured by Cirrus SD-OCT in healthy Indian children 6-17 years of age, which is statistically different from the databases from other countries. It establishes the importance of the fact that age and gender warrants special consideration during cirrus SD-OCT interpretations in children.
印度儿童人群的标准黄斑卷云光谱域光学相干断层扫描数据
目的:无创的卷云光谱域光学相干断层扫描(SD-OCT)在识别、监测和分类儿童玻璃体视网膜疾病方面越来越受欢迎。发达国家的儿童卷云SD-OCT正常值目前可获得,但印度没有。目的:本研究的主要目的是使用cirrus SD-OCT为健康的印度儿童黄斑厚度提供一个规范的儿科数据库。材料与方法:对2013年1月至2014年1月期间157例健康儿童进行前瞻性观察研究。本研究纳入157例无眼部异常、视力正常(20/20)、眼底镜检查正常的受试者。使用Cirrus HD-OCT (Carl Zeiss, Dublin, California, USA)装置。结果:研究患者平均年龄为12.59±3.5岁,其中男性112例(12.88±3.5岁),女性45例(11.8612.88±3.5岁)。线性回归分析发现,年龄的增加对中心子野厚度和外黄斑野的变化有独立的影响(β = - 1.17-1.7, P = 0.004-0.022),且男性显著高于女性(t检验;t = 1.9 ~ 4.8, P = 0.00 ~ 0.24)。结论:本研究建立了印度6-17岁健康儿童Cirrus SD-OCT测量黄斑参数的正常参考值,与其他国家的数据库有统计学差异。它确立了年龄和性别在儿童卷云SD-OCT解释中需要特别考虑的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信