Adhesion of Ligament Periodontal Cells to Different Titanium Surfaces: An In Vitro Comparative Study

L. B. Alves, F. Ginani, José Roberto Bezerra da Silva, C. Alves-Junior, C. Barboza
{"title":"Adhesion of Ligament Periodontal Cells to Different Titanium Surfaces: An In Vitro Comparative Study","authors":"L. B. Alves, F. Ginani, José Roberto Bezerra da Silva, C. Alves-Junior, C. Barboza","doi":"10.4034/PBOCI.V11I4.1020","DOIUrl":null,"url":null,"abstract":"Purpose: the present study aims to evaluate, through experiments in vitro, the adhesion capacity of rats periodontal ligament cells on polishing and treated by ionic nitriding (plasma) titanium surfaces. \nMethod: degree II titanium discs (ASTM F86), 15mm of diameter for 1,5mm of thickness, which had received different treatments from surface in 2 distinct groups (polished and cathodic cage plasma nitriding) were used. The cells were isolated from periodontal ligament of rats and cultivated in α-MEM contend antibiotic and supplemented with 10% of FBS, for 72 hours, in humid atmosphere with 5% of CO2 at 37oC. In the subculture the cells were cultivated on titanium discs in 24-well cell culture plates, with a density of 1 x 104 cells per well, including wells with no discs (control). After 24 hours of cultivation, the cells were counted in a Neubauer chamber. Results: the results had shown that the mean adhesion was greater on the control surface (0.62±0.22) than on polished (0.46±0.14) and nitriding (0.33±0.10) surfaces. Statistical significant difference was observed between the groups control and cathodic cage plasma nitriding (p=0.04), nevertheless no diference was found between polished and nitriding groups. \nConclusion: the adhesion capacity of rat periodontal ligament cells on the titanium surfaces was not influenced by the different surface treatments given to the material, since none of these contributed positively in the process of cellular adhesion.","PeriodicalId":134552,"journal":{"name":"Brazilian Research in Pediatric Dentistry and Integrated Clinic","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Research in Pediatric Dentistry and Integrated Clinic","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4034/PBOCI.V11I4.1020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: the present study aims to evaluate, through experiments in vitro, the adhesion capacity of rats periodontal ligament cells on polishing and treated by ionic nitriding (plasma) titanium surfaces. Method: degree II titanium discs (ASTM F86), 15mm of diameter for 1,5mm of thickness, which had received different treatments from surface in 2 distinct groups (polished and cathodic cage plasma nitriding) were used. The cells were isolated from periodontal ligament of rats and cultivated in α-MEM contend antibiotic and supplemented with 10% of FBS, for 72 hours, in humid atmosphere with 5% of CO2 at 37oC. In the subculture the cells were cultivated on titanium discs in 24-well cell culture plates, with a density of 1 x 104 cells per well, including wells with no discs (control). After 24 hours of cultivation, the cells were counted in a Neubauer chamber. Results: the results had shown that the mean adhesion was greater on the control surface (0.62±0.22) than on polished (0.46±0.14) and nitriding (0.33±0.10) surfaces. Statistical significant difference was observed between the groups control and cathodic cage plasma nitriding (p=0.04), nevertheless no diference was found between polished and nitriding groups. Conclusion: the adhesion capacity of rat periodontal ligament cells on the titanium surfaces was not influenced by the different surface treatments given to the material, since none of these contributed positively in the process of cellular adhesion.
牙周韧带细胞与不同钛表面黏附的体外比较研究
目的:通过体外实验研究大鼠牙周膜细胞对离子氮化(等离子体)钛表面抛光处理的粘附能力。方法:采用直径15mm,厚度15mm的II级钛片(ASTM F86),表面处理分为抛光组和阴极笼等离子体渗氮组。从大鼠牙周膜中分离细胞,在α-MEM抗菌素中培养,并添加10%的胎牛血清,在37℃、5% CO2的潮湿环境中培养72小时。传代培养时,细胞在24孔细胞培养板的钛盘上培养,密度为每孔1 × 104个细胞,包括无盘的孔(对照组)。培养24小时后,在Neubauer室中计数细胞。结果:对照表面的平均附着力(0.62±0.22)大于抛光表面(0.46±0.14)和氮化表面(0.33±0.10)。对照组与阴极笼等离子体渗氮组差异有统计学意义(p=0.04),抛光组与渗氮组差异无统计学意义(p=0.04)。结论:大鼠牙周膜细胞对钛材料表面的粘附能力不受不同表面处理方式的影响,因为不同处理方式对细胞的粘附都没有积极作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信