Ultra-stable Mid-IR quantum cascade laser for high-resolution spectroscopy and metrology

S. Mejri, P. Sow, S. Tokunaga, O. Lopez, A. Goncharov, B. Argence, C. Chardonnet, A. Amy-Klein, C. Daussy, B. Darquié
{"title":"Ultra-stable Mid-IR quantum cascade laser for high-resolution spectroscopy and metrology","authors":"S. Mejri, P. Sow, S. Tokunaga, O. Lopez, A. Goncharov, B. Argence, C. Chardonnet, A. Amy-Klein, C. Daussy, B. Darquié","doi":"10.1109/EFTF.2014.7331475","DOIUrl":null,"url":null,"abstract":"We report the phase-locking of a quantum cascade laser (QCL) at 10 μm to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz. The locked QCL is then used to perform high-resolution linear and saturated absorption spectroscopy of species of interest for applications in precision measurements.","PeriodicalId":129873,"journal":{"name":"2014 European Frequency and Time Forum (EFTF)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 European Frequency and Time Forum (EFTF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EFTF.2014.7331475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We report the phase-locking of a quantum cascade laser (QCL) at 10 μm to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz. The locked QCL is then used to perform high-resolution linear and saturated absorption spectroscopy of species of interest for applications in precision measurements.
用于高分辨率光谱和计量的超稳定中红外量子级联激光器
本文报道了一种量子级联激光器(QCL)在10 μm的次频标准处锁相,该激光器稳定在OsO4的饱和吸收线上。标准的稳定性和准确性被转移到QCL,导致线宽为10 Hz的顺序。锁定的QCL然后用于执行高分辨率线性和饱和吸收光谱的物种感兴趣的应用于精密测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信