Design of Safety Drive Control Unit for AC Signal without Relay Contact

Shuai Han, H. Ding, Pengfei Dai, Yiping Xiao, Shumin Ge, Xiguo Ren
{"title":"Design of Safety Drive Control Unit for AC Signal without Relay Contact","authors":"Shuai Han, H. Ding, Pengfei Dai, Yiping Xiao, Shumin Ge, Xiguo Ren","doi":"10.1145/3487075.3487179","DOIUrl":null,"url":null,"abstract":"Aiming at the deficiencies of the existing AC signal control system with relay interlocking, this paper introduces a safe driving control unit of AC signal without relay contact. Based on the principle of distributed control and the working principle of dual CPU, it could realize distributed control trackside signal of the interlock-zone and stations and safe drive signal. And, it uses the high frequency and high voltage characteristics of power electronic devices to realize the miniaturization and full-electronic control of the signal control system. At the same time, the control unit solves the problems of current surge when the relay is started, complex control circuit and high maintenance cost. Experiments show that the unit runs stably and has strong practicability. It will play an important role in the distributed trackside control system.","PeriodicalId":354966,"journal":{"name":"Proceedings of the 5th International Conference on Computer Science and Application Engineering","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 5th International Conference on Computer Science and Application Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3487075.3487179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aiming at the deficiencies of the existing AC signal control system with relay interlocking, this paper introduces a safe driving control unit of AC signal without relay contact. Based on the principle of distributed control and the working principle of dual CPU, it could realize distributed control trackside signal of the interlock-zone and stations and safe drive signal. And, it uses the high frequency and high voltage characteristics of power electronic devices to realize the miniaturization and full-electronic control of the signal control system. At the same time, the control unit solves the problems of current surge when the relay is started, complex control circuit and high maintenance cost. Experiments show that the unit runs stably and has strong practicability. It will play an important role in the distributed trackside control system.
无继电器触点交流信号安全驱动控制单元的设计
针对现有交流信号继电器联锁控制系统的不足,介绍了一种无继电器触点交流信号安全驱动控制单元。基于集散控制原理和双CPU工作原理,实现了联锁区、车站轨旁信号和安全驱动信号的集散控制。利用电力电子器件的高频高压特性,实现了信号控制系统的小型化和全电子化。同时,该控制单元解决了继电器启动时电流浪涌、控制电路复杂、维护成本高等问题。实验表明,该装置运行稳定,具有较强的实用性。它将在分布式轨旁控制系统中发挥重要作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信