{"title":"Harmonic Analysis of 3-Phase Induction Motor at PT. Indocement Tunggal Prakarsa","authors":"Rahmat Adiprasetya Al Hasibi, Slamet Suripto, Rama Okta Wiyagi, Candra Dwi Sukardi, Y. Jusman, T. Prasetyo","doi":"10.18196/jet.3464","DOIUrl":null,"url":null,"abstract":"In a developing country, the rate of electricity demand is increasing along with the increasing rate of population growth and the rate of economic development of the country. With the growing development of the use of electronic technology in power systems, more and more non-linear equipment is used in the industry. This non-linear equipment can affect power quality because this non-linear load is the primary source of harmonic interference. To minimize the impact of the harmonic generation that occurs on non-linear loads such as induction motors, harmonic filter equipment is needed. This study also compared the current and voltage THD levels based on the IEEE standard and performed calculations to design a single tuned passive filter. This calculation is done because of the emergence of harmonics on a 3-phase induction motor that has exceeded the standard limit, so it must reduce the harmonics. Moreover, disturbances that occur, such as torsion vibrations caused by the interaction of the fundamental harmonic magnetic field, causing higher noise. Furthermore, it leads to additional thermal stress on electric motors, which have an impact on reducing the life of motor insulation. Based on the comparison and analysis obtained that the measured current THD still exceeds the IEEE standard limits. Then the interference that arises in the 3-phase RAW MILL induction motor will have an adverse impact if not handled correctly and adequately.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Technology UMY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18196/jet.3464","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In a developing country, the rate of electricity demand is increasing along with the increasing rate of population growth and the rate of economic development of the country. With the growing development of the use of electronic technology in power systems, more and more non-linear equipment is used in the industry. This non-linear equipment can affect power quality because this non-linear load is the primary source of harmonic interference. To minimize the impact of the harmonic generation that occurs on non-linear loads such as induction motors, harmonic filter equipment is needed. This study also compared the current and voltage THD levels based on the IEEE standard and performed calculations to design a single tuned passive filter. This calculation is done because of the emergence of harmonics on a 3-phase induction motor that has exceeded the standard limit, so it must reduce the harmonics. Moreover, disturbances that occur, such as torsion vibrations caused by the interaction of the fundamental harmonic magnetic field, causing higher noise. Furthermore, it leads to additional thermal stress on electric motors, which have an impact on reducing the life of motor insulation. Based on the comparison and analysis obtained that the measured current THD still exceeds the IEEE standard limits. Then the interference that arises in the 3-phase RAW MILL induction motor will have an adverse impact if not handled correctly and adequately.
PT三相感应电动机谐波分析
在一个发展中国家,电力需求的速度随着人口增长的速度和国家经济发展的速度而增加。随着电子技术在电力系统应用的日益发展,越来越多的非线性设备被应用于工业中。这种非线性设备会影响电能质量,因为这种非线性负载是谐波干扰的主要来源。为了最大限度地减少谐波产生对非线性负载(如感应电动机)的影响,需要谐波滤波设备。本研究还比较了基于IEEE标准的电流和电压THD水平,并进行了计算以设计单个调谐无源滤波器。此计算是由于三相感应电动机谐波的出现超过了标准限制,因此必须减少谐波。此外,干扰的发生,如扭转振动引起的基本谐波磁场的相互作用,造成更高的噪声。此外,它会导致电机产生额外的热应力,从而影响电机绝缘的寿命。通过对比分析得出,实测电流THD仍超过IEEE标准限值。那么在三相RAW MILL感应电动机中产生的干扰如果处理不当,将会产生不利的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信